Detailed Inspection of Pylon, Lower Spar, in Areas of Fasteners at Junction with Lateral Panel, between RIB 1 and RIB 4, LH/RH
TASK 54-51-00-200-018-A
Detailed Inspection of Pylon, Lower Spar, in Areas of Fasteners at Junction with Lateral Panel, between RIB 1 and RIB 4, LH/RH
Refer to the MPD TASK: 545133-01
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 54-51-00-941-069-A ** ON A/C NOT FOR ALL
Subtask 54-51-00-220-068-A ** ON A/C NOT FOR ALL
Subtask 54-51-00-410-069-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2017]
2026.04.01 01:59:50 UTC
Detailed Inspection of Pylon, Lower Spar, in Areas of Fasteners at Junction with Lateral Panel, between RIB 1 and RIB 4, LH/RH
WARNING:
YOU MUST BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE IS SHUTDOWN. THE ENGINE PARTS CAN STAY HOT FOR ALMOST 1 HOUR.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobNOTE: The effectivity of this task is "ALL". To know if this task is applicable to your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 415 | LOWER PYLON |
| 425 | LOWER PYLON |
| 415AL, 415AR, 425AL, 425AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 54-51-21-000-001-A | Removal of the Pylon Lateral Access-Doors |
| TASK 54-51-21-400-001-A | Installation of the Pylon Lateral Access-Doors |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
Subtask 54-51-00-941-069-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start engine 1(2).
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize FADEC 1(2).
Subtask 54-51-00-040-070-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start engine 1(2).
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize FADEC 1(2).
B. Deactivation of the Thrust Reverser
Subtask 54-51-00-010-065-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). C. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, in zone 415
(b) For the right pylon, in zone 425.
(2) Remove the pylon lateral access-doors (Ref. AMM TASK 54-51-21-000-001):
(a) For the left pylon: 415AL 415AR
(b) For the right pylon: 425AL 425AR.
Subtask 54-51-00-110-070-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, in zone 415
(b) For the right pylon, in zone 425.
(2) Remove the pylon lateral access-doors (Ref. AMM TASK 54-51-21-000-001):
(a) For the left pylon: 415AL 415AR
(b) For the right pylon: 425AL 425AR.
D. Cleaning of the Structure
(1) Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
4. Procedure(1) Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
Subtask 54-51-00-220-068-A ** ON A/C NOT FOR ALL
A. Inspection
Lateral Panels between RIB1 and RIB4 ** ON A/C NOT FOR ALL
Lateral Panels between RIB1 and RIB4 ** ON A/C NOT FOR ALL
(1) Do a detailed inspection of the lower spar of the pylon between RIB1 and RIB4. This inspection is applicable to the areas of the fasteners at the junction with the lateral panel, left and right sides.
(2) Make sure that there is no:
(a) Corrosion damage:
5. Close-up
Lateral Panels between RIB1 and RIB4 ** ON A/C NOT FOR ALL
Lateral Panels between RIB1 and RIB4 ** ON A/C NOT FOR ALL (2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 512200 for types of corrosion, inspection, removal and corrosion protection.
- If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for damage classification and corrective action.
Subtask 54-51-00-410-069-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the pylon lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
(a) For the left pylon: 415AL 415AR
(b) For the right pylon: 425AL 425AR.
Subtask 54-51-00-440-070-A ** ON A/C NOT FOR ALL (1) Install the pylon lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
(a) For the left pylon: 415AL 415AR
(b) For the right pylon: 425AL 425AR.
B. Reactivation of the Thrust Reverser
(1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-51-00-942-054-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).