W DOC AIRBUS | AMM A320F

Detailed Inspection of Shackles, Sleeves and Bolts of Pylon to Wing Attachment Fittings at RIB 4


TASK 54-51-00-200-009-A
Detailed Inspection of Shackles, Sleeves and Bolts of Pylon to Wing Attachment Fittings at RIB 4


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
ZONE: 415
ZONE: 425
1. Reason for the Job
Refer to the MPD TASK: 545116-01
DETAILED INSPECTION OF SHACKLES, SLEEVES AND BOLTS OF PYLON TO WING ATTACHMENT FITTINGS AT RIB 4
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
415
LOWER PYLON
425
LOWER PYLON
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
TASK 54-51-17-000-001-A
Removal of the Pylon-to-Wing Forward Attach-Fitting at RIB4
TASK 54-51-17-400-001-A
Installation of the Pylon-to-Wing Forward Attach-Fitting at RIB4
SRM 511100
SRM 512200
3. Job Set-up
Subtask 54-51-00-941-060-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC.
Subtask 54-51-00-010-059-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) At zone 410 for the left pylon
     (b) At zone 420 for the right pylon.
Subtask 54-51-00-020-054-A ** ON A/C NOT FOR ALL
C. Removal of the Components
NOTE: You must do the shackle inspection in two steps to prevent misalignment of the pylon:
Remove the shackle from one side of the pylon. Then do the inspection.
Install the shackle.
Remove the shackle from the other side of the pylon. Then do the inspection.
Install the shackle.
   (1) Remove the shackles, the sleeves and the bolts (Ref. AMM TASK 54-51-17-000-001).
Subtask 54-51-00-110-061-A ** ON A/C NOT FOR ALL
D. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 54-51-00-220-060-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a detailed inspection of the shackles, sleeves and bolts of the pylon-to-wing attachment fittings at RIB4.
   (2) Make sure that there is no:
     (a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 512200 for types of corrosion, inspection, removal and corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for damage classification and related corrective action.
5. Close-up
Subtask 54-51-00-420-055-A ** ON A/C NOT FOR ALL
A. Installation of the Components
   (1) Install the bolts, the sleeves and the shackles (Ref. AMM TASK 54-51-17-400-001).
Subtask 54-51-00-410-060-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 01:59:33 UTC