Inspection for Missing Fasteners on the Pylon Fairing Panels
TASK 54-50-00-200-003-A
Inspection for Missing Fasteners on the Pylon Fairing Panels
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-50-00-941-057-A ** ON A/C NOT FOR ALL
Subtask 54-50-00-210-055-A ** ON A/C NOT FOR ALL
Subtask 54-50-00-440-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:59:05 UTC
Inspection for Missing Fasteners on the Pylon Fairing Panels
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
Subtask 54-50-00-941-057-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overheat maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC.
Subtask 54-50-00-040-052-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overheat maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC.
B. Aircraft Maintenance Configuration
(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-50-00-040-052-C ** ON A/C NOT FOR ALL (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
B. Aircraft Maintenance Configuration
(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
Subtask 54-50-00-010-054-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
(a) For the left pylon, in zone 410
(b) For the right pylon, in zone 420.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
(a) For the left pylon, in zone 410
(b) For the right pylon, in zone 420.
Subtask 54-50-00-210-055-A ** ON A/C NOT FOR ALL
A. Inspection
Fairing Panels - Right Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Right Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Right Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Left Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Left Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Left Pylon ** ON A/C NOT FOR ALL
(1) Inspect the pylon fairing panels for missing fasteners.
(a) Panels with one missing fastener are permitted, in the conditions that follow:
5. Close-up
Fairing Panels - Right Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Right Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Right Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Left Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Left Pylon ** ON A/C NOT FOR ALL
Fairing Panels - Left Pylon ** ON A/C NOT FOR ALL (a) Panels with one missing fastener are permitted, in the conditions that follow:
- No missing fastener permitted on the forward edge of the panel.
- At the start of each row, from the forward edge of the panel, the two first fasteners must not be missing.
Subtask 54-50-00-440-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-50-00-440-052-C ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
A. Aircraft Maintenance Configuration
(1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-012).
Subtask 54-50-00-410-053-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-012).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).