Removal of the Cooling Fan (131-9(A))
TASK 49-52-51-000-002-A
Removal of the Cooling Fan (131-9(A))
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 49-52-51-860-052-A ** ON A/C NOT FOR ALL
Subtask 49-52-51-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:31:28 UTC
Removal of the Cooling Fan (131-9(A))
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 315AL, 316AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 52-41-00-010-001-A | Open the APU Doors for Access |
Subtask 49-52-51-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the panel 25VU, make sure that the APU MASTER SW p/bsw is OFF.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to start the APU.
(4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
Subtask 49-52-51-865-053-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the panel 25VU, make sure that the APU MASTER SW p/bsw is OFF.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to start the APU.
(4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 49-52-51-010-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE below the APU access doors 315AL and 316AR.
(2) Open the APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001).
(3) Set the LIGHT control SW 11LJ to the ON position.
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE below the APU access doors 315AL and 316AR.
(2) Open the APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001).
(3) Set the LIGHT control SW 11LJ to the ON position.
Subtask 49-52-51-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Cooling Fan
(1) Remove the clamps (11) and the fan inlet duct (12).
(2) Remove the clamp (10) from the fan outlet duct (1).
(3) Hold the fan (9) and remove the clamp (3) from the connecting flange and the fan (9).
(4) Remove the transfer tube (7) from the fan (9).
(5) Remove and discard the packings (6) from the transfer tube (7).
(6) Remove Primary Compressor Discharge (PCD) tube (2) from union (4).
(7) Remove union (4) from the fan (9).
(8) Remove and discard packing (5) from union (4).
(9) Remove and discard the packing (8) from the fan (9).
(1) Remove the clamps (11) and the fan inlet duct (12).
(2) Remove the clamp (10) from the fan outlet duct (1).
(3) Hold the fan (9) and remove the clamp (3) from the connecting flange and the fan (9).
(4) Remove the transfer tube (7) from the fan (9).
(5) Remove and discard the packings (6) from the transfer tube (7).
(6) Remove Primary Compressor Discharge (PCD) tube (2) from union (4).
(7) Remove union (4) from the fan (9).
(8) Remove and discard packing (5) from union (4).
(9) Remove and discard the packing (8) from the fan (9).
Cooling Fan