W DOC AIRBUS | AMM A320F

Reactivation of the Air Intake Flap (APS 3200)


TASK 49-16-00-440-002-A
Reactivation of the Air Intake Flap (APS 3200)


ZONE: 313
ZONE: 314
1. Reason for the Job
MMEL 49-10-02B
APU AIR INTAKE FLAP
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
1
FLASHLIGHT
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
313
TAIL CONE APU AIR INTAKE AREA
314
TAIL CONE APU AIR INTAKE AREA
314AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 49-16-00-210-002-A
Detailed Inspection of APU Air Intake, Diffuser Elbow, Seals and Felt Metal (APS 3200)
TASK 49-16-43-000-005-A
Removal of the Catwalk Panel (APS3200)
TASK 49-16-43-400-005-A
Installation of the Catwalk Panel (APS3200)
TASK 52-41-23-010-801-A
Opening of Access Door 314AR
TASK 52-41-23-410-801-A
Closing of Access Door 314AR
3. Job Set-up
Subtask 49-16-00-865-060-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 49-16-00-860-050-A ** ON A/C NOT FOR ALL
B. Get Access
WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
   (1) Put on and attach a safety harness before you start work in the work area
   (2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE below access door 314AR.
   (3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
   (4) If necessary, use a FLASHLIGHT.
   (5) Remove the catwalk panel (Ref. AMM TASK 49-16-43-000-005).
4. Procedure
Subtask 49-16-00-440-050-A ** ON A/C NOT FOR ALL
A. Connection of the Electrical Connectors
   (1) Disconnect the temporary connector from the electrical connector 7527VC-A.
   (2) Remove and discard the TIE WRAP which holds the electrical connector 7527VC-A to the service frame.
   (3) Remove the CAP - BLANKING from the electrical connector 7527VC.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Connect the electrical connector 7527VC-A to the connector 7527VC.
Subtask 49-16-00-865-061-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 49-16-00-440-051-A ** ON A/C NOT FOR ALL
C. Reactivation of the Air Intake Flap
   (1) Do the trouble shooting procedure for the air intake flap-actuator 4015KM (Ref.TSM 49).
   (2) Do the inspection of the air intake system (Ref. AMM TASK 49-16-00-210-002).
   (3) Make an entry in the logbook to show that the air intake flap is reactivated.
5. Close-up
Subtask 49-16-00-860-067-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the catwalk panel (Ref. AMM TASK 49-16-43-400-005).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 01:27:34 UTC