W DOC AIRBUS | AMM A320F

Detailed Inspection of APU Air Intake, Diffuser Elbow, Seals and Felt Metal (APS 3200)


TASK 49-16-00-210-002-A
Detailed Inspection of APU Air Intake, Diffuser Elbow, Seals and Felt Metal (APS 3200)


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 310
1. Reason for the Job
Refer to the MPD TASK: 491600-A1
DETAILED INSPECTION OF APU AIR INTAKE, DIFFUSER ELBOW, SEALS AND FELT METAL
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
1
BRUSH - BRISTLED
No specific
1
CLEANING EQUIPMENT - STEAM
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
98A57103013000
1
TAP TEST-TOOL
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08ABD1)
Aqueous Cleaner-Aircraft Exterior Gel Type -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
310
FUSLG TAIL SECTION AFT OF AFT PRESS BHD
314AR, 315AL, 316AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 49-00-00-100-002-A
Cleaning of the APU Compartment with installed APU (APS 3200)
TASK 49-16-45-400-002-A
Installation of the Air Intake Diffuser and Elbow (APS 3200)
TASK 52-41-00-010-001-A
Open the APU Doors for Access
TASK 52-41-00-410-001-A
Close the APU Doors after Access
TASK 52-41-23-010-801-A
Opening of Access Door 314AR
TASK 52-41-23-410-801-A
Closing of Access Door 314AR
3. Job Set-up
Subtask 49-16-00-865-065-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAPU/FUEL/BLOW OFF/PUMP2QCB14
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
121VUAPU/FUEL/BLOW OFF/CTL1QCK39
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FUEL/LP VALVE/CTL1QFM40
121VUAPU/FUEL/LP VALVE/SPLY2QFM39
121VUAPU/FUEL/PUMP/CTL3QCM38
Subtask 49-16-00-010-058-A ** ON A/C NOT FOR ALL
B. Get Access
F Air Intake System ** ON A/C NOT FOR ALL
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the access doors 315AL and 316AR.
   (2) Open APU access door 315AL (Ref. AMM TASK 52-41-00-010-001).
   (3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
   (4) Remove the service panel (1) from the service frame (2).
4. Procedure
Subtask 49-16-00-020-052-F ** ON A/C NOT FOR ALL
A. Detailed Inspection of the APU Air Intake, Diffuser Elbow, Seals and Felt Metal
   (1) Clean the APU air-intake flap, the air intake duct internally and the APU doors with Aqueous Cleaner-Aircraft Exterior Gel Type - (Material No.08ABD1) and the BRUSH - BRISTLED.
   (2) Let the cleaning agent stay on the surfaces for 30 minutes.
   (3) Flush the cleaning agent from the surfaces with the CLEANING EQUIPMENT - STEAM at the maximum temperature of 130 deg.C (266.00 deg.F) and the maximum pressure of 5 bar (72.5189 psi).
   (4) Let the surfaces dry for 15 minutes.
   (5) Open APU access door 316AR (Ref. AMM TASK 52-41-00-010-001).
   (6) Examine the flexible seals (5), (8) and (10) for wear, tears and porosity. If necessary, replace them.
   (7) Make sure that the seal (5) is in the correct condition.
   (8) Measure the height of the seal (8) in the expanded condition. It must be 20 +1.5 mm or -0 mm (0.7874 +0.0591 in. or +0.0000 in.). If not, replace the seal (8).
   (9) Close APU access door 316AR (Ref. AMM TASK 52-41-00-410-001).
   (10) Make sure that the distance between the APU plenum (12) and the flanges of the elbow assembly (7) is 18 +3 mm or -3 mm (0.709 +0.118 in. or -0.118 in.). If the clearance is incorrect, do the adjustment of the air intake diffuser and elbow (Ref. AMM TASK 49-16-45-400-002).
   (11) Make sure that the APU plenum (12) and the elbow assembly (7) are aligned to the center on all the perimeter with a tolerance of +/- 4 mm (+/- 0.158 in.). If they are not correctly aligned, adjust the APU plenum and elbow assembly (Ref. AMM TASK 49-16-45-400-002).
   (12) Make sure that there are no signs of de-icing contamination. If you find contamination, clean the APU compartment (Ref. AMM TASK 49-00-00-100-002).
   (13) Air intake system
     (a) Examine the external and internal surfaces of the air intake system for delamination, distortion and cracks.
     (b) Examine the diverter for damage.
     (c) Examine the air intake system for damage from ice particles, corrosion, erosion or unwanted objects.
       1 Do a check of the damping plate.
A damage is permitted when:
  • The maximum dimensions of the damage is: width 2 mm, length 5 mm, depth 1 mm.
  • The damage has no effect on inner surface of the plate.
  • The outer surface adjacent to the damage area has no cracks, delamination or other damage.
If you find damage, do the inspection of the damping plate again in 4500 FC.
     (d) Do a tap check:
CAUTION: BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, DAMAGE TO EQUIPMENT CAN OCCUR.
       1 Do a tap check with a 98A57103013000 TAP TEST-TOOL for delamination on all of the felt metal surfaces of the air intake system, the guide surfaces and the guide vanes (6). Do this at distances of 20 mm (0.7874 in.) in rows 20 mm (0.7874 in.) apart.
   (14) Do a tap check for delamination on the external sandwich structure of the air inlet duct (3). Do this check at distances of 20 mm (0.7874 in.) in rows of 20 mm (0.7874 in.) apart.
NOTE: No delamination, distortion or other damage is permitted.
   (15) Do a visual inspection of the air intake nose (9) and the air intake flap (aluminum flap) (11). Make sure that there are no signs of corrosion.
5. Close-up
Subtask 49-16-00-410-058-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the service panel (1) on the service frame (2).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
   (4) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
   (5) Remove the access platform(s).
Subtask 49-16-00-865-066-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAPU/FUEL/BLOW OFF/PUMP2QCB14
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
121VUAPU/FUEL/BLOW OFF/CTL1QCK39
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FUEL/LP VALVE/CTL1QFM40
121VUAPU/FUEL/LP VALVE/SPLY2QFM39
121VUAPU/FUEL/PUMP/CTL3QCM38
[Rev.10 from 2021] 2026.04.01 04:06:46 UTC