Removal of the Vacuum Generator
TASK 38-31-64-000-001-A
Removal of the Vacuum Generator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 38-31-64-861-053-A
Subtask 38-31-64-020-051-B
[Rev.10 from 2021]
2026.04.01 01:20:46 UTC
Removal of the Vacuum Generator
WARNING:
DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING:
ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
- ON THE TOILET WASTE SYSTEM, OR
- ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WARNING:
WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS DISINFECT THE PART BEFORE YOU PUT IT IN A PLASTIC BAG, THEN SEAL THE BAG.
DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST,THEN ATTACH THE DOCUMENTS TO IT.
THIS WILL PREVENT INFECTION OR ILLNESS. CONTAMINATION FROM THE WASTE CAN BE DANGEROUS TO HEALTH.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 37MG
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 2 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.11GCA1) | Deodorant-Aircraft Toilets - - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 161DW, 162DW, 826 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 38-30-00-510-001-A | Decontamination of Components of the Waste/Water and Toilet System for Shipping and/or Installation |
| TASK 38-31-00-680-001-A | Draining of the Toilet System |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-31-64-861-053-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(1) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 38-31-64-680-051-A (Ref. AMM TASK 24-42-00-861-001).
(1) Put the ACCESS PLATFORM 2M (6 FT) in position.
B. Drain Flush and Disinfect the Waste System
(1) Drain and flush the waste tank (Ref. AMM TASK 38-31-00-680-001).
(2) Put 2. l (0.5283 USgal) of Deodorant-Aircraft Toilets - - (Material No.11GCA1) in each toilet bowl and flush them through.
Subtask 38-31-64-865-069-A (1) Drain and flush the waste tank (Ref. AMM TASK 38-31-00-680-001).
(2) Put 2. l (0.5283 USgal) of Deodorant-Aircraft Toilets - - (Material No.11GCA1) in each toilet bowl and flush them through.
NOTE: This procedure is to make sure that the complete toilet system is disinfected.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-31-64-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
D. Get Access
(1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door 826.
(3) Remove the cargo compartment panels 161DW 162DW (Ref. AMM TASK 25-55-12-000-001).
4. Procedure(1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door 826.
(3) Remove the cargo compartment panels 161DW 162DW (Ref. AMM TASK 25-55-12-000-001).
Subtask 38-31-64-020-051-B
A. Removal of the Vacuum Generator 37MG
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the nut (11) and the washer (10).
(4) Remove the bolt (8) and the bonding strap (9).
(5) Remove the clamps (7) and the hose (6).
(6) Remove the clamps (12) and the hose (13).
(7) Remove the bolts (3) and the washers (4).
(8) Remove the vacuum generator (5) 37MG.
(9) If you use the removed parts again, clean them with disinfectant (Ref. AMM TASK 38-30-00-510-001).
WARNING:
ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN YOU DO THIS TASK.
WARNING:
WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS DISINFECT THE PART BEFORE YOU PUT IT IN A PLASTIC BAG, THEN SEAL THE BAG.
DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST,THEN ATTACH THE DOCUMENTS TO IT.
THIS WILL PREVENT INFECTION OR ILLNESS. CONTAMINATION FROM THE WASTE CAN BE DANGEROUS TO HEALTH.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the electrical connectors (1) 37MG-B and (2) 37MG-A. (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the nut (11) and the washer (10).
(4) Remove the bolt (8) and the bonding strap (9).
(5) Remove the clamps (7) and the hose (6).
(6) Remove the clamps (12) and the hose (13).
(7) Remove the bolts (3) and the washers (4).
(8) Remove the vacuum generator (5) 37MG.
(9) If you use the removed parts again, clean them with disinfectant (Ref. AMM TASK 38-30-00-510-001).
NOTE: It is not necessary to use disinfectant to clean the parts that did not touch human waste.
Vacuum Generator 37MG