W DOC AIRBUS | AMM A320F

Removal of the Anti-Syphon Valve


TASK 38-31-56-000-001-A
Removal of the Anti-Syphon Valve


WARNING: DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING: ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
  • ON THE TOILET WASTE SYSTEM, OR
  • ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND WATER. THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).
WARNING: WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS DISINFECT THE PART BEFORE YOU PUT IT IN A PLASTIC BAG, THEN SEAL THE BAG. DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST,THEN ATTACH THE DOCUMENTS TO IT. THIS WILL PREVENT INFECTION OR ILLNESS. CONTAMINATION FROM THE WASTE CAN BE DANGEROUS TO HEALTH.
ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
COVER - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-45-22-000-001-A
Removal of the Toilet Shroud and the Seat
TASK 25-45-22-000-802-A
Removal of the Toilet Shroud of the Space Flex Lavatory
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
TASK 38-30-00-510-001-A
Decontamination of Components of the Waste/Water and Toilet System for Shipping and/or Installation
F Anti-Syphon Valve ** ON A/C NOT FOR ALL
F Anti-Syphon Valve ** ON A/C NOT FOR ALL
F Anti-Syphon Valve ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-31-56-861-050-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-56-865-062-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
Subtask 38-31-56-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the lavatory door.
   (2) Remove the toilet shroud (Ref. AMM TASK 25-45-22-000-001).
   (3) Make sure that the potable water system is depressurized (Ref. AMM TASK 38-10-00-614-002).
Subtask 38-31-56-010-051-I ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the lavatory door.
   (2) Remove the toilet shroud (Ref. AMM TASK 25-45-22-000-001) (Ref. AMM TASK 25-45-22-000-802).
   (3) Make sure that you do the depressurization of the potable water system (Ref. AMM TASK 38-10-00-614-002).
4. Procedure
Subtask 38-31-56-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Anti-Syphon Valve
   (1) Close the potable-water shutoff valve (5).
   (2) Put the WARNING NOTICE(S) in position to tell persons not to open the potable-water shutoff valve (5).
   (3) Put a COVER - BLANKING in the suction port of the toilet bowl.
   (4) Remove the coupling clamp (7).
   (5) Remove the sleeve (8).
   (6) Remove and discard the O-rings (6).
   (7) Remove the nuts (3) and the washers (2).
   (8) Remove the anti-syphon valve (4).
   (9) Remove and discard the O-ring (1).
   (10) Put the PLUG-BLANKING in each disconnected line end.
   (11) If you use the removed parts again, clean and disinfect them (Ref. AMM TASK 38-30-00-510-001).
Subtask 38-31-56-020-050-C ** ON A/C NOT FOR ALL
A. Removal of the Anti-Syphon Valve
   (1) Close the potable-water shutoff valve (4).
   (2) Put the WARNING NOTICE(S) in position to tell persons not to open the potable-water shutoff valve (4).
   (3) Put a COVER - BLANKING in the suction port of the toilet bowl.
   (4) Remove the nuts (3) and the washers (2).
   (5) Remove the anti-syphon valve (1).
   (6) Remove and discard the O-ring (5).
   (7) Put the PLUG-BLANKING in each disconnected line end.
   (8) If you use the removed parts again, clean and disinfect them (Ref. AMM TASK 38-30-00-510-001).
Subtask 38-31-56-020-050-I ** ON A/C NOT FOR ALL
A. Removal of the Anti-Syphon Valve
   (1) Close the potable-water shutoff valve (3).
   (2) Put the WARNING NOTICE(S) in position to tell persons not to open the potable-water shutoff valve (3).
   (3) Put the COVER - BLANKING in the suction port of the toilet bowl.
   (4) Push the fitting (7) and disconnect the tube (2) from the anti-syphon valve (4).
   (5) Unlock the quick-release clamp (8) and remove it from the anti-syphon valve (4).
   (6) Remove the nuts (10), the screws (6) and the washers (5).
   (7) Remove the packing (11) and discard it.
   (8) Remove the anti-syphon valve (4).
   (9) Remove the packing (9) and discard it.
   (10) Put the PLUG-BLANKING in each disconnected line end.
   (11) If you use the removed parts again, clean them with disinfectant (Ref. AMM TASK 38-30-00-510-001).