Remove and Check the Auxiliary Power Unit (APU) Bleed Check-Valve for Condition
TASK 36-12-51-200-001-A
Remove and Check the Auxiliary Power Unit (APU) Bleed Check-Valve for Condition
Refer to the MPD TASK: 361251-01
REMOVE AND CHECK AUXILIARY POWER UNIT BLEED CHECK VALVE FOR CONDITION
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-12-51-860-052-A
Subtask 36-12-51-210-050-A
Subtask 36-12-51-420-053-A Subtask 36-12-51-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:39:15 UTC
Remove and Check the Auxiliary Power Unit (APU) Bleed Check-Valve for Condition
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
1. Reason for the JobRefer to the MPD TASK: 361251-01
REMOVE AND CHECK AUXILIARY POWER UNIT BLEED CHECK VALVE FOR CONDITION
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14FAB1) | Abrasive-- Scotch Brite Pads - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 197 | REAR FAIRING |
| 197BB | |
| 197KB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 36-12-51-000-001-A | Removal of the APU Bleed Check-Valve |
| TASK 36-12-51-400-001-A | Installation of the APU Bleed Check-Valve |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
| TASK 53-35-13-400-002-A | Installation of the Quick-Release Access Panels on the Belly Fairing Structure |
Subtask 36-12-51-860-052-A
A. Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
Subtask 36-12-51-010-051-A ** ON A/C NOT FOR ALL Subtask 36-12-51-010-051-D ** ON A/C NOT FOR ALL Subtask 36-12-51-020-054-A 4. ProcedureSubtask 36-12-51-210-050-A
A. Inspection of the APU Bleed Check-Valve
(1) Make sure that the valve flaps, the hinge pin and/or the spring are not missing in the APU bleed check-valve. If the part(s) is (are) missing:
(a) Do an inspection of the APU bleed-air system and the air conditioning system. Find the part(s) before you install a new APU bleed check-valve.
(2) Examine the APU bleed check-valve for damage:
(a) If the stop and/or the valve flaps on the APU bleed check-valve are worn, remove the marks with a Abrasive-- Scotch Brite Pads - (Material No.14FAB1) .
(3) Make sure that the valve flaps open and close freely.
(4) Make sure that the spring holds the weight of the valve flaps, when the valve flaps are closed.
5. Close-up(1) Make sure that the valve flaps, the hinge pin and/or the spring are not missing in the APU bleed check-valve. If the part(s) is (are) missing:
(a) Do an inspection of the APU bleed-air system and the air conditioning system. Find the part(s) before you install a new APU bleed check-valve.
(2) Examine the APU bleed check-valve for damage:
(a) If the stop and/or the valve flaps on the APU bleed check-valve are worn, remove the marks with a Abrasive-- Scotch Brite Pads - (Material No.14FAB1) .
(3) Make sure that the valve flaps open and close freely.
(4) Make sure that the spring holds the weight of the valve flaps, when the valve flaps are closed.
Subtask 36-12-51-420-053-A Subtask 36-12-51-410-051-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 197BB (Ref. AMM TASK 53-35-13-400-002).
Subtask 36-12-51-410-051-D ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 197BB (Ref. AMM TASK 53-35-13-400-002).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 197KB (Ref. AMM TASK 53-35-13-400-002).
Subtask 36-12-51-942-053-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 197KB (Ref. AMM TASK 53-35-13-400-002).
C. Remove the access platform(s).
APU Bleed Check-Valve