Removal of the Crew Oxygen-Storage Cylinder
TASK 35-11-41-000-001-A
Removal of the Crew Oxygen-Storage Cylinder
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 35-11-41-010-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:42:42 UTC
Removal of the Crew Oxygen-Storage Cylinder
WARNING:
DO NOT FILL OR REPLACE A CREW OXYGEN CYLINDER OR REPLACE A VALVE ASSEMBLY ON THE CREW OXYGEN SYSTEM WHEN YOU FUEL OR DEFUEL THE AIRCRAFT.
KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCES OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING:
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
WARNING:
BE CAREFUL WHEN YOU REMOVE OR INSTALL THIS EQUIPMENT. THIS EQUIPMENT IS HEAVY (MORE THAN 12 KG (26.5 lb)) AND CAN CAUSE INJURY AND/OR DAMAGE.
1. Reason for the JobNOTE: Two persons are necessary to do this task.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 125 | LATERAL AVIONIC COMPARTMENT |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 812 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
Subtask 35-11-41-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(2) Open access door 812.
Subtask 35-11-41-860-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(2) Open access door 812.
B. Aircraft Maintenance Configuration
(1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(3) Fully close the valve of the oxygen storage cylinder (5750HM).
(4) Put a WARNING NOTICE(S) in position to tell persons not to open the valve of the oxygen storage cylinder.
Subtask 35-11-41-614-050-A ** ON A/C NOT FOR ALL (1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(3) Fully close the valve of the oxygen storage cylinder (5750HM).
(4) Put a WARNING NOTICE(S) in position to tell persons not to open the valve of the oxygen storage cylinder.
C. Bleeding of the Oxygen System
(1) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU, push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(2) On one oxygen-mask stowage box, push and hold the PRESS TO TEST AND RESET control lever.
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator.
(a) Keep them pushed for a minimum of three seconds.
(5) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
Subtask 35-11-41-865-050-A ** ON A/C NOT FOR ALL (1) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU, push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(2) On one oxygen-mask stowage box, push and hold the PRESS TO TEST AND RESET control lever.
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator.
(a) Keep them pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and the volume of the sound of the oxygen flow decreases.
(3) When the flow rate indicator is black and when you no longer hear the sound of the oxygen flow: - Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control lever.
(5) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
- Release the CREW SUPPLY pushbutton switch (the OFF legend comes on).
- Put a WARNING NOTICE(S) in position to tell persons not to push the CREW SUPPLY pushbutton switch.
D. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
WARNING:
SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
Subtask 35-11-41-020-053-B ** ON A/C NOT FOR ALL A. Removal of the Crew Oxygen-Storage Cylinder (5750HM)
(2) Put the PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the nut (4) of the oxygen pressure-regulator transmitter (3).
(3) Put the oxygen pressure-regulator transmitter (3) in a BAG - VINYL.
(4) Remove the sealing cap (2) from the bag (11).
(5) Put the sealing cap (2) on the cylinder valve outlet-port (5).
(6) TORQUE the sealing cap (2) to between 4.520 and 3.955 m.daN (33.33 and 29.17 lbf.ft )
.
(7) Disconnect the union (8) from the overpressure outlet port (10).
(8) Discard the ring (7).
(9) Put the PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (8).
(10) Remove the sealing cap (9) from the bag (11).
(11) Put the sealing cap (9) on the overpressure outlet port (10).
(12) Remove the nuts (14) and the washers (13) and disengage the collar assembly (12) from the support (22).
(13) Remove the nut (16) and the spacer (27).
(14) Disengage the pin (25) from the clamp (19).
(15) Open the clamps (19) and (24) and remove the crew oxygen-storage cylinder (1) from the support (22).
Subtask 35-11-41-020-053-E ** ON A/C NOT FOR ALL WARNING:
SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
(1) Loosen the nut (4) and disconnect the oxygen pressure-regulator transmitter (3) from the valve (6). (2) Put the PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the nut (4) of the oxygen pressure-regulator transmitter (3).
(3) Put the oxygen pressure-regulator transmitter (3) in a BAG - VINYL.
(4) Remove the sealing cap (2) from the bag (11).
(5) Put the sealing cap (2) on the cylinder valve outlet-port (5).
(6) TORQUE the sealing cap (2) to between 4.520 and 3.955 m.daN (33.33 and 29.17 lbf.ft )
. (7) Disconnect the union (8) from the overpressure outlet port (10).
(8) Discard the ring (7).
(9) Put the PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (8).
(10) Remove the sealing cap (9) from the bag (11).
(11) Put the sealing cap (9) on the overpressure outlet port (10).
(12) Remove the nuts (14) and the washers (13) and disengage the collar assembly (12) from the support (22).
(13) Remove the nut (16) and the spacer (27).
(14) Disengage the pin (25) from the clamp (19).
(15) Open the clamps (19) and (24) and remove the crew oxygen-storage cylinder (1) from the support (22).
A. Removal of the Crew Oxygen-Storage Cylinder (5750HM)
(1) Loosen the nut (3) and disconnect the oxygen pressure-regulator transmitter (2) from the valve (6).
(2) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the oxygen pressure-regulator transmitter (2).
(3) Put the oxygen pressure-regulator transmitter (2) in a BAG - VINYL.
(4) Remove the sealing cap (4) from the bag (8).
(5) Put the sealing cap (4) on the cylinder valve outlet-port (5).
(6) TORQUE the sealing cap (4) to between 4.520 and 3.955 m.daN (33.33 and 29.17 lbf.ft )
.
(7) Disconnect the union (10) from the cylinder valve outlet-port (7), remove and discard the ring (9).
(8) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (10).
(9) Put an oxygen cylinder stowage-cap on the cylinder valve outlet-port (7) and tighten it.
(10) Loosen the nut (12) and disengage the pin (11) from the clamp (14).
(11) Open the clamps (13) and (14) and remove the oxygen storage cylinder (1) from the support (15).
(1) Loosen the nut (3) and disconnect the oxygen pressure-regulator transmitter (2) from the valve (6).
(2) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the oxygen pressure-regulator transmitter (2).
(3) Put the oxygen pressure-regulator transmitter (2) in a BAG - VINYL.
(4) Remove the sealing cap (4) from the bag (8).
(5) Put the sealing cap (4) on the cylinder valve outlet-port (5).
(6) TORQUE the sealing cap (4) to between 4.520 and 3.955 m.daN (33.33 and 29.17 lbf.ft )
. (7) Disconnect the union (10) from the cylinder valve outlet-port (7), remove and discard the ring (9).
(8) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (10).
(9) Put an oxygen cylinder stowage-cap on the cylinder valve outlet-port (7) and tighten it.
(10) Loosen the nut (12) and disengage the pin (11) from the clamp (14).
(11) Open the clamps (13) and (14) and remove the oxygen storage cylinder (1) from the support (15).
Crew Oxygen-Storage Cylinder