1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
1
PIN - NON METALLIC
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
3. Job Set-up
Subtask 33-24-12-860-068-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 33-24-12-865-075-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN79WLH07
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN79WLH05
** ON A/C NOT FOR ALL
2000VULAV FWD-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2000VULIGHT-LAV1LQJ01
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-OCCUPIED11WJB04
Subtask 33-24-12-010-056-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Get Access to the Ceiling Light in the SMART lavatory:
F Ceiling Light ** ON A/C NOT FOR ALL
     (a) FOR 60LQ*
  • On the upper service panel (9), loosen the two studs (10) to open and lower the service panel (9).
4. Procedure
Subtask 33-24-12-020-057-A ** ON A/C NOT FOR ALL
A. Removal of the Ceiling Light
F Ceiling Light ** ON A/C NOT FOR ALL
   (1) Push the quick-release fastener (5) with PIN - NON METALLIC to disengage it.
   (2) Move the cover (3) to the outboard direction until the hooks (4) release.
   (3) Remove the cover (3).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (4) Disconnect the electrical connector (8).
   (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (6) Cut and discard the TIE WRAPS (7) to release the cable (1).
   (7) Pull the ceiling light (2) to release it from the clamps (6).
   (8) Remove the ceiling light (2).