W DOC AIRBUS | AMM A320F

Removal of Temperature Sensor


TASK 30-73-19-000-001-A
Removal of Temperature Sensor


NOTE: The removal procedure is the same for the temperature sensors 30DW, 40DW, 60DW, 61DW, 70DW, 90DW, 210DW.
ZONE: 150
ZONE: 160
ZONE: 170
FIN: 110DW ** ON A/C NOT FOR ALL
FIN: 30DW ** ON A/C NOT FOR ALL
FIN: 40DW ** ON A/C NOT FOR ALL
FIN: 60DW ** ON A/C NOT FOR ALL
FIN: 61DW ** ON A/C NOT FOR ALL
FIN: 70DW ** ON A/C NOT FOR ALL
FIN: 90DW ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
1
ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
FOR [110DW] (SENSOR,TEMPERATURE-)
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [70DW] (SENSOR,TEMPERATURE-)
FOR [90DW] (SENSOR,TEMPERATURE-)
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
FOR [30DW] (SENSOR,TEMPERATURE-)
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [61DW] (SENSOR,TEMPERATURE-)
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [60DW] (SENSOR,TEMPERATURE-)
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
150
AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT
160
BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT
170
AFT CAB U/FLOOR COMPT AFT BHD OF BULK
FOR [110DW] (SENSOR,TEMPERATURE-)
151CW
FOR [30DW] (SENSOR,TEMPERATURE-)
131NW, 132PW
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [70DW] (SENSOR,TEMPERATURE-)
161CW, 161DW
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [61DW] (SENSOR,TEMPERATURE-)
161DW
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [70DW] (SENSOR,TEMPERATURE-)
FOR [90DW] (SENSOR,TEMPERATURE-)
161CW, 161DW
FOR [60DW] (SENSOR,TEMPERATURE-)
151BW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
FOR [110DW] (SENSOR,TEMPERATURE-)
TASK 25-55-11-000-003-A
Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59
FOR [110DW] (SENSOR,TEMPERATURE-)
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [70DW] (SENSOR,TEMPERATURE-)
FOR [90DW] (SENSOR,TEMPERATURE-)
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
FOR [30DW] (SENSOR,TEMPERATURE-)
TASK 25-54-12-000-001-A
Removal of the Forward Cargo-Compartment Partition
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-003-A
Open the FWD or Aft Cargo-Compartment Door with the Hand Pump
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [70DW] (SENSOR,TEMPERATURE-)
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-003-A
Open the FWD or Aft Cargo-Compartment Door with the Hand Pump
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [61DW] (SENSOR,TEMPERATURE-)
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 52-30-00-860-006-A
Open the Bulk Cargo-Compartment Door
FOR [40DW] (SENSOR,TEMPERATURE-)
FOR [70DW] (SENSOR,TEMPERATURE-)
FOR [90DW] (SENSOR,TEMPERATURE-)
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 25-55-12-000-003-A
Removal of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65
FOR [60DW] (SENSOR,TEMPERATURE-)
TASK 25-55-11-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR47
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 30-73-19-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-73-19-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUPOT/WASTE WIP-HEATER-LINE21DWA03
2000VUPOT/WASTE WIP-HEATER-CTL2DWA01
** ON A/C NOT FOR ALL
2000VUPOT WIP-HEATER-LINE21DWA03
2000VUPOT WIP-HEATER-CTL2DWA01
** ON A/C NOT FOR ALL
2001VUPOT/WASTE WIP-HEATER-LINE51DWD04
2001VUPOT/WASTE WIP-HEATER-LINE31DWD03
2001VUPOT/WASTE WIP-HEATER-CTL32DWD02
Subtask 30-73-19-010-050-B ** ON A/C NOT FOR ALL
C. Get Access
   (1) FOR [30DW] (SENSOR,TEMPERATURE-)
     (a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position after you open the forwward cargo-compartment door.
     (c) Set the cargo-compartment light switch 6LU to ON.
     (d) Remove partition 131NW 132PW (Ref. AMM TASK 25-54-12-000-001).
   (2) FOR [60DW] (SENSOR,TEMPERATURE-)
     (a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position after you open the aft cargo-compartment door.
     (c) Set the cargo-compartment light switch 8LU to ON.
     (d) Remove partition 151BW (Ref. AMM TASK 25-55-11-000-001).
   (3) FOR [40DW] (SENSOR,TEMPERATURE-), [61DW] (SENSOR,TEMPERATURE-)
     (a) Open the bulk cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
     (b) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position after you open the bulk cargo-compartment door.
     (c) Set the cargo-compartment light switch 8LU to ON.
     (d) Remove partition 161DW (Ref. AMM TASK 25-55-12-000-001).
Subtask 30-73-19-010-050-D ** ON A/C NOT FOR ALL
C. Get Access
   (1) FOR [30DW]
   (2) FOR [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-)
Subtask 30-73-19-010-050-K ** ON A/C NOT FOR ALL
C. Get Access
   (1) FOR [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-), [90DW] (SENSOR,TEMPERATURE-), [110DW] (SENSOR,TEMPERATURE-)
     (a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position after you open the aft cargo-compartment door.
     (c) Set the cargo-compartment light switch 8LU to ON position.
   (2) FOR [90DW] (SENSOR,TEMPERATURE-), [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-)
     (a) Remove partition 161DW (Ref. AMM TASK 25-55-12-000-001) and sidewall panel 161CW (Ref. AMM TASK 25-55-12-000-003).
   (3) FOR [110DW] (SENSOR,TEMPERATURE-)
     (a) Remove sidewall panel 151CW (Ref. AMM TASK 25-55-11-000-003).
4. Procedure
Subtask 30-73-19-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Temperature Sensor
   (1) Remove and discard the cable ties which attach the electrical wires of the clamp sensor assembly (3).
   (2) Carefully remove the adhesive tape (7) that attach the longitudinal seam of the insulation (6) in the area of the clamp (4) and clamp sensor assembly (3).
   (3) Loosen the insulation (6) around the clamp (4) and the clamp sensor assembly (3) to get access to the assembly.
CAUTION: MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (4) Disconnect the electrical connections (2) with an ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20.
   (5) Put the CAP - BLANKING on the disconnected electrical connector(s).
   (6) Loosen the screws (1) and remove the clamp sensor assembly (3) and the clamp (4) from the water line (5).
[Rev.10 from 2021] 2026.04.01 08:24:58 UTC