W DOC AIRBUS | AMM A320F

Servicing of the Rain Repellent System


TASK 30-45-00-600-802-A
Servicing of the Rain Repellent System


WARNING: DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
  • FLUSH IT AWAY WITH CLEAN WATER
  • GET MEDICAL AID.
WARNING: THE RAIN REPELLENT FLUID GAGE IS CONSIDERED AS AN ASSEMBLY. THE COMPONENTS OF THIS ASSEMBLY, ESPECIALLY THE PRESSURE GAGE, MUST NOT BE REPLACED ON AIRCRAFT.
WARNING: MAKE SURE THAT YOU DEPRESSURIZE THE RAIN REPELLENT SYSTEM BEFORE YOU REMOVE THE RAIN REPELLENT FLUID-CAN. RAIN REPELLENT FLUID CAN COME OUT SUDDENLY IF YOU REMOVE THE FLUID CAN WITH THE SYSTEM PRESSURIZED.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
ZONE: 210
1. Reason for the Job
To remove a rain-repellent fluid can, to flush the system with a cleaning fluid and to install a new rain-repellent fluid can.
This task is used to drain the remaining fluid and to flush the system at the same time.
This task is applicable for systems that are in operation (not disconnected).
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 3 L(3/4 USGAL)
No specific
1
HOSE - DRAIN
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BBD1)
Non Aqueous Cleaner-- Isopropyl Alcohol -
(Material No.08BFA1)
Non Aqueous Cleaner-Rain Repellent System remover - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
SEAL
AIPC 30-45-01-06-027
7
ORING
AIPC 30-45-01-06-027
3
SEAL
AIPC 30-45-81-06-060
7
SEAL
AIPC 30-45-81-06-060
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 30-45-00-720-002-A
Functional Test of the Rain Repellent System (with the Air Compressor)
TASK 30-45-00-720-002-B
Functional Test of the Rain Repellent System (with the Air Conditioning System)
3. Job Set-up
Subtask 30-45-00-861-058-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-45-00-865-068-A
WARNING: BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE: - THE PROBES WILL BECOME TOO HOT. - THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
B. Open, safety and tag these circuit breakers in this sequence:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
** ON A/C ALL
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
** ON A/C NOT FOR ALL
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
** ON A/C ALL
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
123VUANTI ICE/L/WHSLD1DG1AF10
123VUANTI ICE/R/WHSLD1DG2AF03
49VUANTI ICE/PROBES/PHC/12DA1D03
122VUANTI ICE/PROBES/PHC/22DA2Y12
122VUANTI ICE/PROBES/PHC/32DA3Y16
Subtask 30-45-00-941-068-A
C. On the overhead control and indicating panel 21VU and overhead control and indicating panel 22VU, put a WARNING NOTICE(S) to tell persons not to operate the rain repellent pushbutton switches.
4. Procedure
Subtask 30-45-00-941-069-A
A. Preparation
   (1) Connect a HOSE - DRAIN to the drain valve (5) of the rain-repellent fluid-gage assembly (4).
   (2) Put the hose outlet in a CONTAINER 3 L(3/4 USGAL).
Subtask 30-45-00-870-054-A
B. Depressurization of the System
CAUTION: MAKE SURE THAT THE HOSE OUTLET IS IN THE CONTAINER.
   (1) Push the pushbutton switch (6) to depressurize the system.
   (2) Make sure that no more rain repellent fluid comes out from the hose outlet.
Subtask 30-45-00-020-057-A
C. Removal of the Rain-Repellent Fluid Can
   (1) Remove the clamp (2).
   (2) Loosen and remove the can (1).
   (3) Remove and discard the seal (3).
   (4) Put the PLUG-BLANKING in each disconnected line end.
Subtask 30-45-00-420-058-A
D. Installation of the Flush Can
   (1) Clean the component interface and/or the adjacent area.
   (2) Do a visual inspection of the component interface and/or the adjacent area.
   (3) Remove the blanking plugs from the disconnected line ends.
   (4) Install a new AIPC 30-45-01-06-027 ORING (7) or AIPC 30-45-81-06-060 SEAL (7) into the inlet port of the rain-repellent fluid-gage assembly (4).
   (5) Install the flush can (9) with Non Aqueous Cleaner-Rain Repellent System remover - - (Material No.
08BFA1) on the rain-repellent fluid-gage assembly (4).
   (6) Install the clamp (8) on the flush can (9) and tighten it.
Subtask 30-45-00-865-069-A
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
Subtask 30-45-00-870-055-A
F. Flush the Rain Repellent System with Cleaning Fluid
   (1) Push the RAIN RPLNT pushbutton switches on the overhead control and indicating panels 21VU and 22VU as many times as necessary, until no fluid flows through the spray nozzle.
Subtask 30-45-00-865-070-A
G. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
Subtask 30-45-00-100-055-A
H. Cleaning of the Windshield
   (1) Clean the windshield with Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) to remove the remaining fluid.
Subtask 30-45-00-020-059-A
I. Removal of the Flush Can
   (1) Remove the clamp (8).
   (2) Loosen and remove the flush can (9).
   (3) Remove and discard the seal (7).
Subtask 30-45-00-420-059-A Subtask 30-45-00-210-055-A
K. Inspection/Check
   (1) Push the pushbutton switch (6) of the rain-repellent fluid-gage assembly (4).
   (2) Make sure that the fluid level is correct and that the pressure increases to the correct level.
   (3) Make sure that there are no leaks.
   (4) Disconnect the HOSE - DRAIN from the drain valve (5) of the rain-repellent fluid-gage assembly (4).
Subtask 30-45-00-720-054-A
5. Close-up
Subtask 30-45-00-865-071-A
A. Remove the safety clips and tags and close these circuit breakers in this sequence:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUANTI ICE/PROBES/PHC/12DA1D03
122VUANTI ICE/PROBES/PHC/22DA2Y12
122VUANTI ICE/PROBES/PHC/32DA3Y16
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
** ON A/C ALL
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
** ON A/C NOT FOR ALL
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
** ON A/C ALL
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
123VUANTI ICE/L/WHSLD1DG1AF10
123VUANTI ICE/R/WHSLD1DG2AF03
Subtask 30-45-00-942-060-A
B. Remove the WARNING NOTICE(S).
Subtask 30-45-00-862-057-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 00:31:02 UTC