Installation of the RAT Interlock Proximity Switch
TASK 29-22-51-400-011-A
Installation of the RAT Interlock Proximity Switch
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 29-22-51-860-101-A
Subtask 29-22-51-420-066-A
Subtask 29-22-51-860-102-A
[Rev.10 from 2021]
2026.04.01 00:26:16 UTC
Installation of the RAT Interlock Proximity Switch
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 2 | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.249 and 0.226 m.daN (22.04 and 20.00 lbf.in ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-22-00-710-007-A | Operational Test of the Manual Deployment and the Retraction of the Ram Air Turbine |
| TASK 29-22-00-820-005-A | Adjustment of the RAT Interlock Proximity Switch |
| TASK 29-22-00-869-005-A | Extension of the Ram Air Turbine (RAT) on the Ground |
Subtask 29-22-51-860-101-A
A. Aircraft Maintenance Configuration
(1) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration (Ref. AMM TASK 29-00-00-864-001).
(2) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Blue hydraulic system:
(4) Make sure that the RAT is extended (Ref. AMM TASK 29-22-00-869-005).
Subtask 29-22-51-865-098-A (1) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration (Ref. AMM TASK 29-00-00-864-001).
(2) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Blue hydraulic system:
- in the cockpit on the hydraulic section 40VU of the overhead panel,
- on the ground service panel of the Blue hydraulic system.
(4) Make sure that the RAT is extended (Ref. AMM TASK 29-22-00-869-005).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | D14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | B13 |
| ** ON A/C ALL | |||
| 106VU | CSM/G /EV/MAN/SPLY | 6XE | B04 |
| 121VU | HYDRAULIC/RAT/SPLY/EXTN/SOL1 | 2803GE | P33 |
Subtask 29-22-51-420-066-A
A. Installation of the Interlock Proximity Switch
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install the interlock proximity switch (2) with the bolts (7), the washers (6), the shim (4) and the nuts (3). Refer to the marks on the attachment bracket to find the correct installation position.
(4) TORQUE the nuts (3) to between 0.249 and 0.226 m.daN (22.04 and 20.00 lbf.in )
.
(5) Remove the protective caps from the electrical connectors.
(6) Make sure that all the electrical connections are clean and in the correct condition.
(7) Connect the electrical connector (5).
Subtask 29-22-51-865-099-A (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install the interlock proximity switch (2) with the bolts (7), the washers (6), the shim (4) and the nuts (3). Refer to the marks on the attachment bracket to find the correct installation position.
(4) TORQUE the nuts (3) to between 0.249 and 0.226 m.daN (22.04 and 20.00 lbf.in )
. (5) Remove the protective caps from the electrical connectors.
(6) Make sure that all the electrical connections are clean and in the correct condition.
(7) Connect the electrical connector (5).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 29-22-51-710-057-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | D14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | B13 |
| ** ON A/C ALL | |||
| 106VU | CSM/G /EV/MAN/SPLY | 6XE | B04 |
| 121VU | HYDRAULIC/RAT/SPLY/EXTN/SOL1 | 2803GE | P33 |
C. Adjustment of the Interlock Proximity Switch and Test
(1) Do the adjustment of the interlock proximity switch (Ref. AMM TASK 29-22-00-820-005).
(2) Do an operational test of the manual deployment and the retraction of the RAT (Ref. AMM TASK 29-22-00-710-007).
5. Close-up(1) Do the adjustment of the interlock proximity switch (Ref. AMM TASK 29-22-00-820-005).
(2) Do an operational test of the manual deployment and the retraction of the RAT (Ref. AMM TASK 29-22-00-710-007).
Subtask 29-22-51-860-102-A
A. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
RAT Interlock Proximity Switch