Removal of the Manual Selector Valve
TASK 29-16-51-000-001-A
Removal of the Manual Selector Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-16-51-860-052-A
Subtask 29-16-51-020-050-A
[Rev.10 from 2021]
2026.04.01 08:10:21 UTC
Removal of the Manual Selector Valve
FIN: 1134GQ
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 2 | CAP - BLANKING |
| No specific | 1 | CONTAINER 3 L(3/4 USGAL) |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 197BB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
Subtask 29-16-51-860-052-A
A. Aircraft Maintenance Configuration
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems:
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoirs of the Green ,Yellow and Blue hydraulic systems (Ref. AMM TASK 29-14-00-614-001).
(5) Put the CONTAINER 3 L(3/4 USGAL) below the hydraulic connections to collect the hydraulic fluid.
Subtask 29-16-51-010-050-A WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002). (2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems:
- in the cockpit on the hydraulic section 40VU of the overhead panel.
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoirs of the Green ,Yellow and Blue hydraulic systems (Ref. AMM TASK 29-14-00-614-001).
(5) Put the CONTAINER 3 L(3/4 USGAL) below the hydraulic connections to collect the hydraulic fluid.
B. Get Access
(1) Remove the access panel 197BB.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the ground service panel of the Green hydraulic system.
Subtask 29-16-51-865-050-A (1) Remove the access panel 197BB.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the ground service panel of the Green hydraulic system.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/HYD/QTY/IND | 1831GQ | P35 |
Subtask 29-16-51-020-050-A
A. Removal of the Manual Selector Valve
(2) Put a CAP - BLANKING on the disconnected electrical connector (1) and on the receptacle (2).
(3) Loosen the union nut (3) and disconnect the pipe from the adapter (4) installed in port Y of the valve assembly (17).
(4) Loosen the union nut (20) and disconnect the pipe from the adapter (19) installed in port G of the valve assembly (17).
(5) Loosen the union nut (10) and disconnect the pipe from the adapter (11) installed in port A of the valve assembly (17).
(6) Loosen the union nut (9) and disconnect the pipe from the adapter (8) installed in port B of the valve assembly (17).
(7) Put the PLUG-BLANKING in each disconnected line end.
(8) Remove the nuts (13), the screw (16) and the washer (15) and disconnect the bonding jumper (14) from the manual selector (17).
(9) Support the manual selector valve assembly (17).
(10) Remove the screws (21) and the washers (22).
(11) Pull the manual selector valve (17) out of the back of the service panel (6).
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. IF YOU DO NOT USE THE SECOND WRENCH, THERE IS A RISK THAT YOU WILL LOOSEN OR TIGHTEN THE UNION TOO MUCH.
(1) Disconnect the electrical connector (1) from the receptacle (2). (2) Put a CAP - BLANKING on the disconnected electrical connector (1) and on the receptacle (2).
(3) Loosen the union nut (3) and disconnect the pipe from the adapter (4) installed in port Y of the valve assembly (17).
(4) Loosen the union nut (20) and disconnect the pipe from the adapter (19) installed in port G of the valve assembly (17).
(5) Loosen the union nut (10) and disconnect the pipe from the adapter (11) installed in port A of the valve assembly (17).
(6) Loosen the union nut (9) and disconnect the pipe from the adapter (8) installed in port B of the valve assembly (17).
(7) Put the PLUG-BLANKING in each disconnected line end.
(8) Remove the nuts (13), the screw (16) and the washer (15) and disconnect the bonding jumper (14) from the manual selector (17).
(9) Support the manual selector valve assembly (17).
(10) Remove the screws (21) and the washers (22).
(11) Pull the manual selector valve (17) out of the back of the service panel (6).
Reservoir Selector Valve (1134GQ)