W DOC AIRBUS | AMM A320F

Removal of the Hydraulic Fluid Separator


TASK 29-14-42-000-001-A
Removal of the Hydraulic Fluid Separator


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 2 L (0.53 USGAL)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
195BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
3. Job Set-up
Subtask 29-14-42-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
** ON A/C NOT FOR ALL
49VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKH12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKR35
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR34
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR33
** ON A/C ALL
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-14-42-941-050-A
B. Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green, Blue and Yellow hydraulic systems:
  • In the cockpit on the hydraulic section 40VU of the overhead panel,
  • On the ground service panel of the Green, Blue and Yellow hydraulic systems.
Subtask 29-14-42-860-050-B
C. Aircraft Maintenance Configuration
   (1) Make sure that the hydraulic systems are depressurized and put them in the maintenance configuration
(Ref. AMM TASK 29-00-00-864-001).
   (2) Depressurize the reservoirs of the Green, Blue and Yellow hydraulic systems (Ref. AMM TASK 29-14-00-614-001).
   (3) Put a CONTAINER 2 L (0.53 USGAL) below the water separator.
   (4) Drain the fluid from the water separator into the container.
   (5) Remove the container.
Subtask 29-14-42-010-050-A
D. Open the access panel 195BB.
4. Procedure
Subtask 29-14-42-020-050-B
A. Removal of the Water Separator
   (1) Hold the water separator (3) and remove the bolts (4).
   (2) Disengage the water separator (3) from the reservoir pressurization unit (2).
   (3) Remove and discard the packings (5) and (6).