Removal of the Air Relief Valve of the Green Hydraulic System
TASK 29-14-17-000-001-A
Removal of the Air Relief Valve of the Green Hydraulic System
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 29-14-17-865-050-A
Subtask 29-14-17-020-050-A
[Rev.10 from 2021]
2026.04.01 08:09:22 UTC
Removal of the Air Relief Valve of the Green Hydraulic System
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 1005GM
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 2 | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
Subtask 29-14-17-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-14-17-860-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYDRAULIC/G HYD/PUMP ENG1/CTL | 1701GK | H12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/CTL | 1701GK | R35 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/LOW/LVL/IND | 1832GQ | N32 |
| 121VU | HYDRAULIC/HYD/QTY/IND | 1831GQ | P35 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R33 |
B. Aircraft Maintenance Configuration
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic system:
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoir of the Green hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(5) Open the right hand door of the main gear (Ref. AMM TASK 32-12-00-010-001).
(6) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
4. Procedure(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic system:
- In the cockpit on the hydraulic section 40VU of the overhead panel,
- On the ground service panel of the Green hydraulic system.
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoir of the Green hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(5) Open the right hand door of the main gear (Ref. AMM TASK 32-12-00-010-001).
(6) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
Subtask 29-14-17-020-050-A
A. Removal of the Air Relief Valve
(2) Hold the air relief valve (2) and disconnect the union nut (1).
(3) Remove the air relief valve (2) and discard the O-ring (3).
(4) Install a PLUG - BLANKING on the open connections.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. IF YOU DO NOT USE THE SECOND WRENCH, THERE IS A RISK THAT YOU WILL LOOSEN OR TIGHTEN THE UNION TOO MUCH.
(1) Cut, remove and discard the lockwire. (2) Hold the air relief valve (2) and disconnect the union nut (1).
(3) Remove the air relief valve (2) and discard the O-ring (3).
(4) Install a PLUG - BLANKING on the open connections.
Pressure Relief Valve