Removal of the Inline Damper of the Green Engine Pump
TASK 29-11-46-000-802-A
Removal of the Inline Damper of the Green Engine Pump
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-11-46-860-059-A
Subtask 29-11-46-020-053-A
[Rev.10 from 2021]
2026.04.01 00:16:32 UTC
Removal of the Inline Damper of the Green Engine Pump
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
DO NOT GET HYDRAULIC FLUID ON YOUR SKIN, IN YOUR EYES OR IN YOUR MOUTH. HYDRAULIC FLUID IS POISONOUS AND CAN GO THROUGH YOUR SKIN AND INTO YOUR BODY. FLUSH HYDRAULIC FLUID FROM YOUR EYES, MOUTH OR SKIN WITH WATER. GET MEDICAL AID IF YOU GET HYDRAULIC FLUID IN YOUR EYES OR MOUTH.
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
CAUTION:
DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CONTAINER 5 L (1.32 USGAL) |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH - STANDARD |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 430 | ENG 1 AIR INTAKE, FAN AND ACCESS GEARBOX |
| 195BB, 197CB | |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
Subtask 29-11-46-860-059-A
A. Aircraft Maintenance Configuration
(1) Make sure that the Green hydraulic system is depressurized
(Ref. AMM TASK 29-10-00-864-001).
(2) Depressurize the reservoir of the Green hydraulic system
(Ref. AMM TASK 29-14-00-614-001).
Subtask 29-11-46-941-054-A (1) Make sure that the Green hydraulic system is depressurized
(Ref. AMM TASK 29-10-00-864-001).
(2) Depressurize the reservoir of the Green hydraulic system
(Ref. AMM TASK 29-14-00-614-001).
B. Safety Precautions
(1) On AIR COND panel 30VU:
(a) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system on the ground service panel.
(3) On the HYD section of panel 40VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the reservoir of the Green hydraulic system.
(5) On the center pedestal, on ENG panel 115VU:
Subtask 29-11-46-010-059-A (1) On AIR COND panel 30VU:
- Make sure that the APU BLEED pushbutton switch is released (ON legend off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate this pushbutton switch.
(a) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system on the ground service panel.
(3) On the HYD section of panel 40VU:
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system.
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the reservoir of the Green hydraulic system.
(5) On the center pedestal, on ENG panel 115VU:
- Make sure that the ENG/MODE selector switch is in the NORM position.
- Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
- Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
- Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
Subtask 29-11-46-020-053-A
A. Removal of the Inline Damper of the Green Engine Pump
(2) Hold the damper (1) with a WRENCH - STANDARD and disconnect the hydraulic pressure hose (2).
(3) Drain the hydraulic fluid from the hydraulic pressure hose (2) into the CONTAINER 5 L (1.32 USGAL).
(4) Remove the damper (1) from the hydraulic pump (3).
(5) Remove and discard the retainers (4).
(6) Remove and discard the packings (5) and (6).
(7) Install COVER - PROTECTION on the hydraulic pressure hose (2), damper (1) and hydraulic pump (3).
CAUTION:
WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE AND ADJACENT COMPONENTS.
CAUTION:
USE TWO WRENCHES TO REMOVE OR INSTALL THE TUBE COUPLING NUTS:
(1) Put a CONTAINER 5 L (1.32 USGAL) below the hydraulic pressure hose connection. - ONE WRENCH TO HOLD THE UNION, AND
- ONE TO LOOSEN OR TIGHTEN THE COUPLING NUT.
(2) Hold the damper (1) with a WRENCH - STANDARD and disconnect the hydraulic pressure hose (2).
(3) Drain the hydraulic fluid from the hydraulic pressure hose (2) into the CONTAINER 5 L (1.32 USGAL).
(4) Remove the damper (1) from the hydraulic pump (3).
(5) Remove and discard the retainers (4).
(6) Remove and discard the packings (5) and (6).
(7) Install COVER - PROTECTION on the hydraulic pressure hose (2), damper (1) and hydraulic pump (3).
Inline Damper of the Green Engine Pump