Removal of the Accumulator-Air Pressure Gage
TASK 29-11-21-000-001-A
Removal of the Accumulator-Air Pressure Gage
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-11-21-865-050-A
Subtask 29-11-21-614-051-A
[Rev.10 from 2021]
2026.04.01 07:51:01 UTC
Removal of the Accumulator-Air Pressure Gage
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | 2 | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 2 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 147 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 29-23-00-860-001-A | Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
Subtask 29-11-21-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-11-21-860-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYDRAULIC/G HYD/PUMP ENG1/CTL | 1701GK | H12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/CTL | 1701GK | R35 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/SOL VALVES/G/Y/B/LEAK/TST | 1881GP | N35 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R33 |
B. Aircraft Maintenance Configuration
(1) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system:
(Ref. AMM TASK 29-00-00-864-001).
(3) Depressurize the reservoir of the Green hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) Open the left main door of the main gear (Ref. AMM TASK 32-12-00-010-001).
(5) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the left door of the main gear.
(6) Disconnect the isolation coupling of the Power Transfer Unit (PTU) (Ref. AMM TASK 29-23-00-860-001).
4. Procedure(1) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system:
- in the cockpit on the hydraulic section 40VU of the overhead panel,
- on the ground service panel of the Green hydraulic system.
(Ref. AMM TASK 29-00-00-864-001).
(3) Depressurize the reservoir of the Green hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) Open the left main door of the main gear (Ref. AMM TASK 32-12-00-010-001).
(5) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the left door of the main gear.
(6) Disconnect the isolation coupling of the Power Transfer Unit (PTU) (Ref. AMM TASK 29-23-00-860-001).
Subtask 29-11-21-614-051-A
A. Depressurization of the Power Accumulator (1070GM)
(1) Remove the endcap from the charging valve (5).
(2) Turn the nut to the OPEN position and release the nitrogen pressure.
Subtask 29-11-21-020-050-A (1) Remove the endcap from the charging valve (5).
(2) Turn the nut to the OPEN position and release the nitrogen pressure.
B. Removal of the Pressure Gage
(1) Cut, remove and discard the lockwire from the pressure gage (2).
(2) Hold the pressure gage (2) and release the nut (3).
(3) Remove the pressure gage (2).
(4) Install a PLUG - BLANKING on the pressure gage and the adapter.
(1) Cut, remove and discard the lockwire from the pressure gage (2).
(2) Hold the pressure gage (2) and release the nut (3).
(3) Remove the pressure gage (2).
(4) Install a PLUG - BLANKING on the pressure gage and the adapter.
Pressure Gage