Discard Cartridge
TASK 26-22-42-920-001-A
Discard Cartridge
1. Reason for the Job
Refer to the MPD TASK: 262242-01
DISCARD CARTRIDGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 26-22-42-941-051-A
Subtask 26-22-42-920-050-A ** ON A/C NOT FOR ALL
Subtask 26-22-42-865-055-A
[Rev.10 from 2021]
2026.03.31 23:45:43 UTC
Discard Cartridge
1. Reason for the Job
Refer to the MPD TASK: 262242-01
DISCARD CARTRIDGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | 1 | BAG - ELECTROSTATIC SAFETY |
| No specific | 1 | FLASHLIGHT |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 6971-0010 | 1 | CAP SHUNT-FIRE BOTTLE |
| MS25043-10DA | 1 | CARTRIDGE CAP |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 313 | TAIL CONE APU AIR INTAKE AREA |
| 314AR |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 2 | CARTRIDGE | AIPC 26-22-04-01-055 |
| 2 | CARTRIDGE | AIPC 26-22-84-01-110 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-22-42-000-001-A | Removal of the Fire-Extinguisher Bottle Cartridge |
| TASK 26-22-42-400-001-A | Installation of the Fire-Extinguisher Bottle Cartridge |
| TASK 52-41-23-010-801-A | Opening of Access Door 314AR |
| TASK 52-41-23-410-801-A | Closing of Access Door 314AR |
Subtask 26-22-42-941-051-A
A. Put a WARNING NOTICE(S) in position on panel 25VU to tell persons not to operate the APU.
Subtask 26-22-42-865-054-A B. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-22-42-010-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
C. Get Access
(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) If necessary, use a FLASHLIGHT.
4. ProcedureWARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(1) Put on and attach a safety harness before you start work in the work area(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) If necessary, use a FLASHLIGHT.
Subtask 26-22-42-920-050-A ** ON A/C NOT FOR ALL
A. Remove and Discard the APU Fire Extinguisher Bottle Cartridge (12WF).
(1) Remove the cartridge (Ref. AMM TASK 26-22-42-000-001).
(a) Make sure that the MS25043-10DA CARTRIDGE CAP is installed on the cartridge.
(b) Make sure that the cartridge is in an BAG - ELECTROSTATIC SAFETY.
(2) Install the new AIPC 26-22-04-01-055 CARTRIDGE (2) or AIPC 26-22-84-01-110 CARTRIDGE (2) (Ref. AMM TASK 26-22-42-400-001).
(3) Send the cartridge to the workshop for disposal.
Subtask 26-22-42-920-050-B ** ON A/C NOT FOR ALL (1) Remove the cartridge (Ref. AMM TASK 26-22-42-000-001).
(a) Make sure that the MS25043-10DA CARTRIDGE CAP is installed on the cartridge.
(b) Make sure that the cartridge is in an BAG - ELECTROSTATIC SAFETY.
(2) Install the new AIPC 26-22-04-01-055 CARTRIDGE (2) or AIPC 26-22-84-01-110 CARTRIDGE (2) (Ref. AMM TASK 26-22-42-400-001).
(3) Send the cartridge to the workshop for disposal.
A. Remove and Discard the APU Fire Extinguisher Bottle Cartridge (12WF).
(1) Remove the cartridge (Ref. AMM TASK 26-22-42-000-001).
(a) Make sure that the 6971-0010 CAP SHUNT-FIRE BOTTLE is installed on the cartridge.
(b) Make sure that the cartridge is in an BAG - ELECTROSTATIC SAFETY.
(2) Install the new AIPC 26-22-04-01-055 CARTRIDGE (2) (Ref. AMM TASK 26-22-42-400-001).
(3) Send the cartridge to the workshop for disposal.
5. Close-up(1) Remove the cartridge (Ref. AMM TASK 26-22-42-000-001).
(a) Make sure that the 6971-0010 CAP SHUNT-FIRE BOTTLE is installed on the cartridge.
(b) Make sure that the cartridge is in an BAG - ELECTROSTATIC SAFETY.
(2) Install the new AIPC 26-22-04-01-055 CARTRIDGE (2) (Ref. AMM TASK 26-22-42-400-001).
(3) Send the cartridge to the workshop for disposal.
Subtask 26-22-42-865-055-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-22-42-410-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).