W DOC AIRBUS | AMM A320F

Discard Cartridge


TASK 26-22-42-920-001-A
Discard Cartridge


ZONE: 313
FIN: 12WF
1. Reason for the Job
Refer to the MPD TASK: 262242-01
DISCARD CARTRIDGE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
1
BAG - ELECTROSTATIC SAFETY
No specific
1
FLASHLIGHT
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
6971-0010
1
CAP SHUNT-FIRE BOTTLE
MS25043-10DA
1
CARTRIDGE CAP
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
313
TAIL CONE APU AIR INTAKE AREA
314AR
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
CARTRIDGE
AIPC 26-22-04-01-055
2
CARTRIDGE
AIPC 26-22-84-01-110
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 26-22-42-000-001-A
Removal of the Fire-Extinguisher Bottle Cartridge
TASK 26-22-42-400-001-A
Installation of the Fire-Extinguisher Bottle Cartridge
TASK 52-41-23-010-801-A
Opening of Access Door 314AR
TASK 52-41-23-410-801-A
Closing of Access Door 314AR
3. Job Set-up
Subtask 26-22-42-941-051-A
A. Put a WARNING NOTICE(S) in position on panel 25VU to tell persons not to operate the APU.
Subtask 26-22-42-865-054-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
Subtask 26-22-42-010-051-A
C. Get Access
WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
   (1) Put on and attach a safety harness before you start work in the work area
   (2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
   (3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
   (4) If necessary, use a FLASHLIGHT.
4. Procedure
Subtask 26-22-42-920-050-A ** ON A/C NOT FOR ALL
A. Remove and Discard the APU Fire Extinguisher Bottle Cartridge (12WF).
   (1) Remove the cartridge (Ref. AMM TASK 26-22-42-000-001).
     (a) Make sure that the MS25043-10DA CARTRIDGE CAP is installed on the cartridge.
     (b) Make sure that the cartridge is in an BAG - ELECTROSTATIC SAFETY.
   (2) Install the new AIPC 26-22-04-01-055 CARTRIDGE (2) or AIPC 26-22-84-01-110 CARTRIDGE (2) (Ref. AMM TASK 26-22-42-400-001).
   (3) Send the cartridge to the workshop for disposal.
Subtask 26-22-42-920-050-B ** ON A/C NOT FOR ALL
A. Remove and Discard the APU Fire Extinguisher Bottle Cartridge (12WF).
   (1) Remove the cartridge (Ref. AMM TASK 26-22-42-000-001).
     (a) Make sure that the 6971-0010 CAP SHUNT-FIRE BOTTLE is installed on the cartridge.
     (b) Make sure that the cartridge is in an BAG - ELECTROSTATIC SAFETY.
   (2) Install the new AIPC 26-22-04-01-055 CARTRIDGE (2) (Ref. AMM TASK 26-22-42-400-001).
   (3) Send the cartridge to the workshop for disposal.
5. Close-up
Subtask 26-22-42-865-055-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
Subtask 26-22-42-410-054-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.03.31 23:45:43 UTC