W DOC AIRBUS | AMM A320F

Visual Inspection of the Engine-Fan Fire-Extinguishing Tube-Assembly


TASK 26-21-49-210-001-A
Visual Inspection of the Engine-Fan Fire-Extinguishing Tube-Assembly


ZONE: 430
ZONE: 440
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
430
ENG 1 AIR INTAKE, FAN AND ACCESS GEARBOX
440
ENG 2 AIR INTAKE, FAN AND ACCESS GEARBOX
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 26-21-49-000-003-A
Removal of the Engine Fire-Extinguisher Tube-Assembly
TASK 26-21-49-400-003-A
Installation of the Engine Fire-Extinguisher Tube-Assembly
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 26-21-49-941-059-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the panel 115VU:
  • put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
   (2) Make sure that the engine shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the maintenance panel 50VU:
  • make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off
  • put a WARNING NOTICE(S).
Subtask 26-21-49-010-062-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 26-21-49-865-061-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q43
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE2Q42
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q41
4. Procedure
Subtask 26-21-49-210-053-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the Fire Extinguisher Tubes Assembly installed on the inlet cowl.
F Fire Extinguisher Tube Assembly ** ON A/C NOT FOR ALL
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Examine the fire extinguisher tube assembly, look for:


A.Cracks, splits or kinks.
None permitted.
Replace the tube (Ref. AMM TASK 26-21-49-000-003) and (Ref. AMM TASK 26-21-49-400-003).
B.Wrinkles in bends.
Maximum depth cannot be more than 3 percent of the tube diameter or 0.06 in. (1.5240 mm) which ever is smaller.
If wrinkles are more than the allowable limits, replace the tube (Ref. AMM TASK 26-21-49-000-003) and (Ref. AMM TASK 26-21-49-400-003).
C.Dents.
Maximum depth cannot be more than 10 percent of the tube outside diameter. Maximum radius must be less than 2 times the wall thickness. Maximum of 2 dents for each 1 ft. (0.30 m) of tube length.
If the dents are more than the allowable limits, replace the tube (Ref. AMM TASK 26-21-49-000-003) and (Ref. AMM TASK 26-21-49-400-003).
D.Flat areas.
Maximum flat area cannot be more than 2 times the tube outside diameter. The contour change cannot be more than 10 percent of the tube outside diameter.
If the flat areas are more than the allowable limits, replace the tube (Ref. AMM TASK 26-21-49-000-003) and (Ref. AMM TASK 26-21-49-400-003).
E.Nicks, scratches, chafing.
Maximum depth cannot be more than 10 percent of the wall thickness.
If the damage is more than the allowage limits, replace the tube (Ref. AMM TASK 26-21-49-000-003) and (Ref. AMM TASK 26-21-49-400-003).
5. Close-up
Subtask 26-21-49-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 26-21-49-865-062-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q43
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE2Q42
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q41