Installation of the Low-Frequency Underwater Locator Beacon (ULB)
TASK 25-65-36-400-801-A
Installation of the Low-Frequency Underwater Locator Beacon (ULB)
Self explanatory
2. Job Set-up Information
A. Consumable Materials
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-65-36-860-050-A ** ON A/C NOT FOR ALL
Subtask 25-65-36-420-050-A ** ON A/C NOT FOR ALL
Subtask 25-65-36-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:41:34 UTC
Installation of the Low-Frequency Underwater Locator Beacon (ULB)
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBD1) | Non Aqueous Cleaner-- Isopropyl Alcohol - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 152HW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-55-11-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 25-55-11-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 25-65-00-710-802-A | Operational Check of the Low-Frequency Underwater Locator Beacon (ULB) |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 25-65-36-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the aft cargo-compartment door is opened (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the light switch is set to the ON position.
(4) Make sure that sidewall panel 152HW is removed (Ref. AMM TASK 25-55-11-000-003).
4. Procedure(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the aft cargo-compartment door is opened (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the light switch is set to the ON position.
(4) Make sure that sidewall panel 152HW is removed (Ref. AMM TASK 25-55-11-000-003).
Subtask 25-65-36-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Underwater Locator Beacon
(1) Put the underwater locator beacon (1) in position and install the washers (3) and the screws (2).
(2) Make sure that the sensors (4) point to the forward direction.
(3) Make sure that the sensors (4) and the insulation around them are clean and free of grease and dirt.
If necessary, clean the sensors (4) with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) .
(4) Install the washer (5) and the screw (6) (Ref. AMM TASK 20-28-00-912-802).
(5) Tighten the screws (6) and (2).
Subtask 25-65-36-710-050-A ** ON A/C NOT FOR ALL (1) Put the underwater locator beacon (1) in position and install the washers (3) and the screws (2).
(2) Make sure that the sensors (4) point to the forward direction.
(3) Make sure that the sensors (4) and the insulation around them are clean and free of grease and dirt.
If necessary, clean the sensors (4) with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) .
(4) Install the washer (5) and the screw (6) (Ref. AMM TASK 20-28-00-912-802).
(5) Tighten the screws (6) and (2).
B. Operational Test
(1) Do the operational test of the underwater locator beacon (Ref. AMM TASK 25-65-00-710-802).
5. Close-up(1) Do the operational test of the underwater locator beacon (Ref. AMM TASK 25-65-00-710-802).
Subtask 25-65-36-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install sidewall panel 152HW (Ref. AMM TASK 25-55-11-400-003).
(3) Set the light switch to off.
(4) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 25-65-36-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install sidewall panel 152HW (Ref. AMM TASK 25-55-11-400-003).
(3) Set the light switch to off.
(4) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Underwater Locator Beacon