Reactivation of the Galley-Waste-Compartment Access Door (If Installed)
TASK 25-35-00-440-802-A
Reactivation of the Galley-Waste-Compartment Access Door (If Installed)
1. Reason for the Job
MMEL 25-35-02A
GALLEY WASTE COMPARTMENT ACCESS DOOR (IF INSTALLED)
2. Job Set-up Information
A. Consumable Materials
B. Referenced Information
3. Job Set-up
Subtask 25-35-00-860-093-A
Subtask 25-35-00-440-051-A
Subtask 25-35-00-860-094-A
[Rev.10 from 2021]
2026.03.31 23:34:13 UTC
Reactivation of the Galley-Waste-Compartment Access Door (If Installed)
1. Reason for the Job
MMEL 25-35-02A
GALLEY WASTE COMPARTMENT ACCESS DOOR (IF INSTALLED)
2. Job Set-up Information
A. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RAB9) | Adhesive Film Tape-- Aluminium Foil - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-35-00-440-001-A | Reactivation of the Galley-Waste-Compartment Flapper-Door |
Subtask 25-35-00-860-093-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
Subtask 25-35-00-010-097-A (1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) In the galley with the defective access door:
4. Procedure(1) In the galley with the defective access door:
- Get access to the galley-waste-compartment.
Subtask 25-35-00-440-051-A
A. Reactivation
(1) Remove the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) .
(2) If necessary, repair or replace the galley-waste-compartment access door as specified in the related galley component maintenance-manual.
(3) Make sure that the access door:
(5) Reactivate the galley-waste compartment flapper door (Ref. AMM TASK 25-35-00-440-001).
(6) Make an entry in the logbook.
5. Close-up(1) Remove the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) .
(2) If necessary, repair or replace the galley-waste-compartment access door as specified in the related galley component maintenance-manual.
(3) Make sure that the access door:
- Operates correctly
- Is aligned with the surface
- Closes and seals fully.
(5) Reactivate the galley-waste compartment flapper door (Ref. AMM TASK 25-35-00-440-001).
(6) Make an entry in the logbook.
Subtask 25-35-00-860-094-A
A. Aircraft Maintenance Configuration
(1) Make sure that the work area is clean and clear of tools and other items.
(2) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).