W DOC AIRBUS | AMM A320F

Deactivation of the Galley-Waste-Compartment Access Door (If Installed)


TASK 25-35-00-040-802-A
Deactivation of the Galley-Waste-Compartment Access Door (If Installed)


1. Reason for the Job
MMEL 25-35-02A
GALLEY WASTE COMPARTMENT ACCESS DOOR (IF INSTALLED)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05RAB9)
Adhesive Film Tape-- Aluminium Foil -
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 25-35-00-040-001-A
Deactivation of the Galley-Waste-Compartment Flapper-Door
3. Job Set-up
Subtask 25-35-00-860-092-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
Subtask 25-35-00-010-096-A
B. Get Access
   (1) In the galley with the defective access door:
  • Get access to the galley-waste-compartment.
4. Procedure
Subtask 25-35-00-040-051-A
A. Deactivation
   (1) Make sure that the waste container is empty.
   (2) Deactivate the galley-waste-compartment flapper door (Ref. AMM TASK 25-35-00-040-001).
   (3) Close the access door and attach it to the galley with Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) to make sure that it cannot open.
   (4) Put the WARNING NOTICE(S) in position to tell persons not to use the galley-waste-compartment.
   (5) Make an entry in the logbook.
5. Close-up
Subtask 25-35-00-862-083-A
A. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 23:34:13 UTC