W DOC AIRBUS | AMM A320F

Deactivation of the Galley-Waste-Compartment Flapper-Door


TASK 25-35-00-040-001-A
Deactivation of the Galley-Waste-Compartment Flapper-Door


Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONONO0.20.21
1. Reason for the Job
MMEL 25-35-01A
GALLEY WASTE COMPARTMENT FLAPPER DOOR (IF INSTALLED)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05RAB9)
Adhesive Film Tape-- Aluminium Foil -
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 25-35-00-861-077-A
A. There is no special job set-up for this task.
4. Procedure
Subtask 25-35-00-040-050-A
A. Deactivation of the Defective or Missing Waste-Compartment Flapper-Door
   (1) Seal the opening of the waste chute with self adhesive tape Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) .
   (2) Put a WARNING NOTICE(S) in position to tell persons not to use the waste compartment.
   (3) Open the access door of the waste compartment:
     (a) Make sure that the waste container is empty.
5. Close-up
Subtask 25-35-00-410-067-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door of the waste compartment.
   (3) Make an entry in the logbook.
[Rev.10 from 2021] 2026.03.31 23:34:10 UTC