Deactivation of the Crew Foot Warmers (FAA Operators Only)
TASK 25-15-00-040-801-A
Deactivation of the Crew Foot Warmers (FAA Operators Only)
MMEL 25-15-01
CREW FOOT WARMERS (FAA ONLY)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-15-00-860-050-A ** ON A/C NOT FOR ALL
Subtask 25-15-00-040-050-A ** ON A/C NOT FOR ALL
Subtask 25-15-00-860-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:29:26 UTC
Deactivation of the Crew Foot Warmers (FAA Operators Only)
ZONE: 211
ZONE: 212
FIN: 2DR1 ** ON A/C NOT FOR ALL
FIN: 2DR2 ** ON A/C NOT FOR ALL
FIN: 2DR3 ** ON A/C NOT FOR ALL
FIN: 2DR4 ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 212
FIN: 2DR1 ** ON A/C NOT FOR ALL
FIN: 2DR2 ** ON A/C NOT FOR ALL
FIN: 2DR3 ** ON A/C NOT FOR ALL
FIN: 2DR4 ** ON A/C NOT FOR ALL
MMEL 25-15-01
CREW FOOT WARMERS (FAA ONLY)
NOTE: The deactivation of the crew foot warmers is applicable only to the FAA operators.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
Subtask 25-15-00-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) FOR [2DR1] (WARMER-FOOT, CAPT R), [2DR3] (WARMER-FOOT, CAPT L)
On CAPT LIGHTING/LOUDSPEAKER control-panel 301VU, make sure that the FOOT WARMER control switch (3DR1) is set to the OFF position.
(3) FOR [2DR2] (WARMER-FOOT, F/O R), [2DR4] (WARMER-FOOT, F/O L)
On F/O LIGHTING/LOUDSPEAKER control-panel 500VU, make sure that the FOOT WARMER control switch (3DR2) is set to the OFF position.
Subtask 25-15-00-865-050-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) FOR [2DR1] (WARMER-FOOT, CAPT R), [2DR3] (WARMER-FOOT, CAPT L)
On CAPT LIGHTING/LOUDSPEAKER control-panel 301VU, make sure that the FOOT WARMER control switch (3DR1) is set to the OFF position.
(3) FOR [2DR2] (WARMER-FOOT, F/O R), [2DR4] (WARMER-FOOT, F/O L)
On F/O LIGHTING/LOUDSPEAKER control-panel 500VU, make sure that the FOOT WARMER control switch (3DR2) is set to the OFF position.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | FOOT WARMER | 1DR | X15 |
Subtask 25-15-00-040-050-A ** ON A/C NOT FOR ALL
A. Deactivation of the Crew Foot Warmers
(1) Open, safety and tag this(these) circuit breaker(s):
5. Close-up(1) Open, safety and tag this(these) circuit breaker(s):
- [1DR] .
Subtask 25-15-00-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make an entry in the logbook.
(2) Make sure that the work area is clean and clear of tools and other items.
(1) Make an entry in the logbook.
(2) Make sure that the work area is clean and clear of tools and other items.