W DOC AIRBUS | AMM A320F

Deactivation of the Crew Foot Warmers (FAA Operators Only)


TASK 25-15-00-040-801-A
Deactivation of the Crew Foot Warmers (FAA Operators Only)


ZONE: 211
ZONE: 212
FIN: 2DR1 ** ON A/C NOT FOR ALL
FIN: 2DR2 ** ON A/C NOT FOR ALL
FIN: 2DR3 ** ON A/C NOT FOR ALL
FIN: 2DR4 ** ON A/C NOT FOR ALL
1. Reason for the Job
MMEL 25-15-01
CREW FOOT WARMERS (FAA ONLY)
NOTE: The deactivation of the crew foot warmers is applicable only to the FAA operators.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
3. Job Set-up
Subtask 25-15-00-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
   (2) FOR [2DR1] (WARMER-FOOT, CAPT R), [2DR3] (WARMER-FOOT, CAPT L)
On CAPT LIGHTING/LOUDSPEAKER control-panel 301VU, make sure that the FOOT WARMER control switch (3DR1) is set to the OFF position.
   (3) FOR [2DR2] (WARMER-FOOT, F/O R), [2DR4] (WARMER-FOOT, F/O L)
On F/O LIGHTING/LOUDSPEAKER control-panel 500VU, make sure that the FOOT WARMER control switch (3DR2) is set to the OFF position.
Subtask 25-15-00-865-050-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUFOOT WARMER1DRX15
4. Procedure
Subtask 25-15-00-040-050-A ** ON A/C NOT FOR ALL
A. Deactivation of the Crew Foot Warmers
   (1) Open, safety and tag this(these) circuit breaker(s):
5. Close-up
Subtask 25-15-00-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make an entry in the logbook.
   (2) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.03.31 23:29:26 UTC