W DOC AIRBUS | AMM A320F

Programming of a NON SMOKER A/C


TASK 23-73-00-860-006-A
Programming of a NON SMOKER A/C


ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 23-73-00-861-001-A
Energize the Cabin Intercommunication Data System (CIDS)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
3. Job Set-up
Subtask 23-73-00-860-144-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
Subtask 23-73-00-865-164-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUL/G/LGCIU/SYS1/NORM1GAC09
49VUAIR COND/CAB/PRESS/CTL11HLD09
121VUENGINE/ENG2/FADEC B4KS2Q40
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
122VUAIR COND/CAB PRESS/CTL/22HLY22
4. Procedure
Subtask 23-73-00-869-073-A ** ON A/C NOT FOR ALL
A. Programming of a NON SMOKER A/C
F Programming of a NON SMOKER A/C ** ON A/C NOT FOR ALL
   (1) On the Programming and Test Panel (PTP) 110RH, push the DSPL ON membrane switch.
  • the CIDS menu page shows.
   (2) Push the <PROGRAMMING related membrane switch.
  • the PROGRAMMING menu page shows.
   (3) Push the <ZONING related membrane switch.
  • the ZONING menu page shows.
   (4) Push the NS SIGNS> related membrane switch.
  • the NS SIGNS / NORMAL SIGNS MODE menu page shows.

NOTE: If the NS SIGNS / NON SMOKER A/C SELECTED page shows, a NON SMOKER A/C is already programmed.
   (5) Push the NON SMKR A/C> related membrane switch.
  • the NS SIGNS / NON SMOKER A/C SELECTED status shows.
  • in the cabin, all NS SIGNS come on.
  • in the cabin, you hear a single LO chime.
   (6) Push the <RET related membrane switch to save the new configuration to layout M.
  • the message PARAMETER SAVING flashes a few seconds and the menu PARAMETER SAVED with the modification number shows.
   (7) Push the <RET related membrane switch.
5. Close-up
Subtask 23-73-00-869-075-A ** ON A/C NOT FOR ALL
A. Push the DSPL ON membrane switch.