Programming of a NON SMOKER A/C
TASK 23-73-00-860-006-A
Programming of a NON SMOKER A/C
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 23-73-00-860-144-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-869-073-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-869-075-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 05:37:34 UTC
Programming of a NON SMOKER A/C
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-73-00-861-001-A | Energize the Cabin Intercommunication Data System (CIDS) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
Subtask 23-73-00-860-144-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
Subtask 23-73-00-865-164-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 49VU | AIR COND/CAB/PRESS/CTL1 | 1HL | D09 |
| 121VU | ENGINE/ENG2/FADEC B | 4KS2 | Q40 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R41 |
| 122VU | AIR COND/CAB PRESS/CTL/2 | 2HL | Y22 |
Subtask 23-73-00-869-073-A ** ON A/C NOT FOR ALL
A. Programming of a NON SMOKER A/C
(1) On the Programming and Test Panel (PTP) 110RH, push the DSPL ON membrane switch.
5. Close-up(1) On the Programming and Test Panel (PTP) 110RH, push the DSPL ON membrane switch.
- the CIDS menu page shows.
- the PROGRAMMING menu page shows.
- the ZONING menu page shows.
- the NS SIGNS / NORMAL SIGNS MODE menu page shows.
NOTE: If the NS SIGNS / NON SMOKER A/C SELECTED page shows, a NON SMOKER A/C is already programmed.
(5) Push the NON SMKR A/C> related membrane switch. - the NS SIGNS / NON SMOKER A/C SELECTED status shows.
- in the cabin, all NS SIGNS come on.
- in the cabin, you hear a single LO chime.
- the message PARAMETER SAVING flashes a few seconds and the menu PARAMETER SAVED with the modification number shows.
Subtask 23-73-00-869-075-A ** ON A/C NOT FOR ALL
A. Push the DSPL ON membrane switch.
Programming of a NON SMOKER A/C