W DOC AIRBUS | AMM A320F

Passenger Address (PA) Level Adjustment via PTP


TASK 23-73-00-860-004-A
Passenger Address (PA) Level Adjustment via PTP


NOTE: This task is only valid if the DIRECTOR OBRM minimum standard 117 is installed.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 23-73-00-860-005-A
Passenger Address (PA) Level Interrogation via CFDS
TASK 23-73-00-861-001-A
Energize the Cabin Intercommunication Data System (CIDS)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
F PA Level Adjustment Example ** ON A/C NOT FOR ALL
F PA Level Adjustment Example ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 23-73-00-860-140-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
Subtask 23-73-00-865-243-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUL/G/LGCIU/SYS1/NORM1GAC09
49VUAIR COND/CAB/PRESS/CTL11HLD09
121VUENGINE/ENG2/FADEC B4KS2Q40
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
122VUAIR COND/CAB PRESS/CTL/22HLY22
4. Procedure
Subtask 23-73-00-869-069-A ** ON A/C NOT FOR ALL
A. PA level adjustment
F PA Level Adjustment Example ** ON A/C NOT FOR ALL
F PA Level Adjustment Example ** ON A/C NOT FOR ALL
   (1) On the PTP 110RH push the DSPL ON pushbutton switch.
  • the CIDS menu page comes on.
   (2) Push the <PROGRAMMING related membrane switch.
  • the PROGRAMMING menu page comes on.
   (3) Push the <CABIN PROGRAMMING related membrane switch.
  • the ENTER ACCESS CODE page comes on.
   (4) Enter the access code 333 123 to the scratchpad field and push the <ENTER related membrane switch.
  • the next page with the <PA LEVEL ADJ message comes on.
   (5) Push the <PA LEVEL ADJ related membrane switch.
  • the PA LEVEL ADJ page comes on.
   (6) push the <CABIN IN DETAIL related membrane switch.
  • the CABIN SEG page comes on.
NOTE: The cabin segments are not equivalent to the cabin zones. The locations of the cabin segments are shown in the CFDS PA LEVEL REPORT (Ref. AMM TASK 23-73-00-860-005).
   (7) Push the related SEG membrane switch to select the cabin segment.
  • the respective segment value flashes.
  • the <+ (DB) and <- (DB) prompts appear.
   (8) Push the + or - related membrane switches to change the PA level value.
NOTE: The values are adjustable in 2 dB steps. The respective PA level in the cabin is updated immediately.
   (9) Select the next cabin segment for updating or push the CONT> related membrane switch to get access to the ATTND page.
   (10) After the update of all PA levels push the <RET related membrane switch to save the new PA levels.
NOTE: If a reset to the default PA level is necessary, select the related cabin segment or attendant station and push the <RES related membrane switch. Pushing the <RES related membrane switch, without selection of a cabin segment or an attendant station, resets all to the default values.
   (11) For an update of the auto increase of the PA level select the <AUTO INCREASE membrane switch on the PA LEVEL ADJ page. The procedure is the same as for the cabin segment and attendant station PA level adjustment.
5. Close-up
Subtask 23-73-00-869-070-A ** ON A/C NOT FOR ALL
A. Push the DSPL On pushbutton switch.
[Rev.10 from 2021] 2026.03.31 23:16:39 UTC