Removal of the Seat Power Box/Unit / Overhead Distribution Box
TASK 23-36-23-000-802-A
Removal of the Seat Power Box/Unit / Overhead Distribution Box
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-36-23-861-051-A ** ON A/C NOT FOR ALL Subtask 23-36-23-010-051-F ** ON A/C NOT FOR ALL
Subtask 23-36-23-020-051-E ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 05:25:51 UTC
Removal of the Seat Power Box/Unit / Overhead Distribution Box
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | STEPLADDER 1.0 M (3.3 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 220 | FWD CAB UTILITY AREAS |
| 230 | FWD PASSENGER COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-36-31-000-801-A | Removal of the Modem Processor Unit / Remote Modem Unit (RMU) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
Subtask 23-36-23-861-051-A ** ON A/C NOT FOR ALL Subtask 23-36-23-010-051-F ** ON A/C NOT FOR ALL
B. Get Access
(1) Put a STEPLADDER 1.0 M (3.3 FT) below the left Overhead Stowage Compartment (OHSC) between frames FR20 and FR21.
(2) Open the access doors of the overhead stowage compartment and the Video Control Center (VCC) (1).
(3) Remove the closeout panel (2):
(a) Release the fasteners (3) and hold the closeout panel (2).
(b) Remove the nut (6), washers (5), screw (7) and bonding strap (4).
(c) Safety the bonding strap (4) in the VCC (1).
(d) Remove the closeout panel (2).
(4) If necessary, remove the Remote Modem Unit (99MH) (Ref. AMM TASK 23-36-31-000-801).
Subtask 23-36-23-865-059-A ** ON A/C NOT FOR ALL (1) Put a STEPLADDER 1.0 M (3.3 FT) below the left Overhead Stowage Compartment (OHSC) between frames FR20 and FR21.
(2) Open the access doors of the overhead stowage compartment and the Video Control Center (VCC) (1).
(3) Remove the closeout panel (2):
(a) Release the fasteners (3) and hold the closeout panel (2).
(b) Remove the nut (6), washers (5), screw (7) and bonding strap (4).
(c) Safety the bonding strap (4) in the VCC (1).
(d) Remove the closeout panel (2).
(4) If necessary, remove the Remote Modem Unit (99MH) (Ref. AMM TASK 23-36-31-000-801).
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | IFE-VCC-AC | 21MH | C02 |
| 2000VU | IFE-VCC-DC | 20MH | C01 |
| 2000VU | WAP | 27MH | D07 |
Subtask 23-36-23-020-051-E ** ON A/C NOT FOR ALL
A. Removal of the Seat Power Unit (SPU)
(2) Disconnect the electrical connectors (9) and (10) from the receptacles (12) and (13).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Release the fasteners (8) and carefully remove the SPU (11) from the VCC (1).
WARNING:
DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
COOL TO PREVENT BURNS.
CAUTION:
TO PREVENT POSSIBLE CROSS-CONNECTION OF THE ELECTRICAL CONNECTORS, MAKE SURE THAT PLUGS AND RECEPTACLES ARE CLEARLY IDENTIFIED.
(1) Put the identification marks on the electrical connectors (9), (10) and the receptacles (12), (13) before you disconnect them. This is important for the subsequent installation procedure. (2) Disconnect the electrical connectors (9) and (10) from the receptacles (12) and (13).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Release the fasteners (8) and carefully remove the SPU (11) from the VCC (1).
Seat Power Unit (SPU)