W DOC AIRBUS | AMM A320F

Removal of the Seat Power Box/Unit / Overhead Distribution Box


TASK 23-36-23-000-802-A
Removal of the Seat Power Box/Unit / Overhead Distribution Box


ZONE: 220
ZONE: 230
FIN: 36MH ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
STEPLADDER 1.0 M (3.3 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
220
FWD CAB UTILITY AREAS
230
FWD PASSENGER COMPARTMENT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 23-36-31-000-801-A
Removal of the Modem Processor Unit / Remote Modem Unit (RMU)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
3. Job Set-up
Subtask 23-36-23-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 23-36-23-010-051-F ** ON A/C NOT FOR ALL
B. Get Access
F Seat Power Unit (SPU) ** ON A/C NOT FOR ALL
   (1) Put a STEPLADDER 1.0 M (3.3 FT) below the left Overhead Stowage Compartment (OHSC) between frames FR20 and FR21.
   (2) Open the access doors of the overhead stowage compartment and the Video Control Center (VCC) (1).
   (3) Remove the closeout panel (2):
     (a) Release the fasteners (3) and hold the closeout panel (2).
     (b) Remove the nut (6), washers (5), screw (7) and bonding strap (4).
     (c) Safety the bonding strap (4) in the VCC (1).
     (d) Remove the closeout panel (2).
   (4) If necessary, remove the Remote Modem Unit (99MH) (Ref. AMM TASK 23-36-31-000-801).
Subtask 23-36-23-865-059-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUIFE-VCC-AC21MHC02
2000VUIFE-VCC-DC20MHC01
2000VUWAP27MHD07
4. Procedure
Subtask 23-36-23-020-051-E ** ON A/C NOT FOR ALL
A. Removal of the Seat Power Unit (SPU)
F Seat Power Unit (SPU) ** ON A/C NOT FOR ALL
WARNING: DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS.
CAUTION: TO PREVENT POSSIBLE CROSS-CONNECTION OF THE ELECTRICAL CONNECTORS, MAKE SURE THAT PLUGS AND RECEPTACLES ARE CLEARLY IDENTIFIED.
   (1) Put the identification marks on the electrical connectors (9), (10) and the receptacles (12), (13) before you disconnect them. This is important for the subsequent installation procedure.
   (2) Disconnect the electrical connectors (9) and (10) from the receptacles (12) and (13).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Release the fasteners (8) and carefully remove the SPU (11) from the VCC (1).
[Rev.10 from 2021] 2026.03.31 23:14:34 UTC