W DOC AIRBUS | AMM A320F

Lubrication of Exterior Control Handle and Telescopic Arm


TASK 12-22-52-640-013-A
Lubrication of Exterior Control Handle and Telescopic Arm


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 833
ZONE: 834
ZONE: 835
ZONE: 843
ZONE: 844
ZONE: 845
1. Reason for the Job
Refer to the MPD TASK: 522200-03
LUBRICATION OF EXTERIOR CONTROL HANDLE AND TELESCOPIC ARM
NOTE: This task is not applicable for deactivated emergency doors.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
GUN - GREASE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03GBC1)
Synthetic Oil base Grease-General Purpose Lithium Thickened Low Temp. -
(Material No.03HBD9)
Synthetic Ester base Grease-General Purpose Low Temp -
(Material No.03JBA1)
Silicone base Grease-General Purpose - -
(Material No.12ABE2)
Corrosion Preventive Compound-Water Displacing Oily Film System
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833
EMERGENCY EXITS
834
EMERGENCY EXITS
835
MID PASSENGER/CREW DOOR
843
EMERGENCY EXITS
844
EMERGENCY EXITS
845
MID PASSENGER/CREW DOOR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-22-00-860-004-A
Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 12-22-00-00
LUBRICATION - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 12-22-52-010-063-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open the applicable emergency exit door (referred to as door) as required (Ref. AMM TASK 52-22-00-010-001).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the partly opened door.
   (3) Make sure that the special precaution on the door damper and emergency operation cylinder is completed (Ref. AMM TASK 52-22-00-860-003).
4. Procedure
Subtask 12-22-52-640-062-A ** ON A/C NOT FOR ALL
A. Lubrication of the External Control Handle and the Telescopic Arm
   (1) Lubrication of the external control handle as follows:
     (a) Apply Silicone base Grease-General Purpose - - (Material No.03JBA1) on the pivot points.
     (b) Remove the unwanted grease with the Textile-Lint free Cotton - (Material No.14SBA1) .
   (2) Lubrication of the telescopic arm (1) of the door damper and emergency operation cylinder as follows:
     (a) Clean the lubrication fitting with the Textile-Lint free Cotton - (Material No.14SBA1) .
     (b) Use the GUN - GREASE to fill the fitting until the new Synthetic Ester base Grease-General Purpose Low Temp - (Material No.03HBD9) or Synthetic Oil base Grease-General Purpose Lithium Thickened Low Temp. - (Material No.03GBC1) comes out. Refer to the lubricant grease specification and lubrication requirements (Ref. AMM D/O 12-22-00-00).
     (c) Remove the unwanted grease with the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Apply Corrosion Preventive Compound-Water Displacing Oily Film System (Material No.12ABE2) on the inner surface and adjacent area of the external control handle.
Subtask 12-22-52-640-062-B ** ON A/C NOT FOR ALL
A. Lubrication of the External Control Handle and the Telescopic Arm
   (1) Lubrication of the external control handle as follows:
     (a) Apply Silicone base Grease-General Purpose - - (Material No.03JBA1) on the pivot points.
     (b) Remove the unwanted grease with the Textile-Lint free Cotton - (Material No.14SBA1) .
   (2) Lubrication of the telescopic arm (1) of the door damper and emergency operation cylinder as follows:
     (a) Clean the lubrication fitting with the Textile-Lint free Cotton - (Material No.14SBA1) .
     (b) Use the GUN - GREASE to fill the fitting until the new Synthetic Oil base Grease-General Purpose Lithium Thickened Low Temp. - (Material No.03GBC1) comes out.
     (c) Remove the unwanted grease with the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Apply Corrosion Preventive Compound-Water Displacing Oily Film System (Material No.12ABE2) on the inner surface and the adjacent area of the external control handle.
5. Close-up
Subtask 12-22-52-410-062-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Do the special precaution for the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
   (3) Close the applicable door (Ref. AMM TASK 52-22-00-410-001).
   (4) Remove the access platform(s).