W DOC AIRBUS | AMM A320F

Draining of the Oil from the Integrated Drive Generator (IDG)


TASK 12-13-24-680-040-B
Draining of the Oil from the Integrated Drive Generator (IDG)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: WEAR GOGGLES, INSULATED GLOVES AND OTHER PROTECTIVE CLOTHES. HOT OIL CAN BURN YOUR EYES AND SKIN. IF OIL TOUCHES YOUR EYES OR SKIN, GET MEDICAL AID.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT USE SOLVENTS THAT CONTAIN CHLORINE TO CLEAN THE EQUIPMENT (PUMP, HOSES, TANK AND FUNNEL) USED TO FILL THE IDG WITH OIL. CHLORINE CONTAMINATION OF THE OIL CAN CAUSE FAST DETERIORATION OF THE OIL AND WILL DECREASE THE LIFE OF THE IDG.
CAUTION: DO NOT OPERATE THE IDG:
  • IF IT CONTAINS TOO MUCH OIL
  • IF IT DOES NOT CONTAIN ENOUGH OIL
IF YOU DO, YOU CAN CAUSE DAMAGE TO THE IDG.
CAUTION: DO NOT DO THE SERVICING OF A DISCONNECTED IDG. CONTINUED OPERATION OF A DEFECTIVE IDG CAN CAUSE DAMAGE.
NOTE: Airbus recommends that you do not do the servicing of more than one IDG at a time.
ZONE: 435
ZONE: 436
ZONE: 445
ZONE: 446
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 10 L(2 1/2 USGAL)
No specific
1
FILLING EQUIPMENT - TANK OIL
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 75 and 55 lbf.in (0.85 and 0.62 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP8001)
lockwire 0.032 in. (0.8 mm) dia.
(Material No.03ABA1)
Synthetic base Lubricating Oil-Turbine Engine - -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
435
FAN AND ACCESSORY GEARBOX
436
FAN AND ACCESSORY GEARBOX
445
FAN AND ACCESSORY GEARBOX
446
FAN AND ACCESSORY GEARBOX
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
8
PACKING
AIPC 24-21-51-02-020
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 24-21-00-612-043-B
Servicing of the Integrated Drive Generator (IDG) after Oil Chemical Contamination
TASK 24-21-00-612-043-B-01
Servicing of the IDG after Oil Chemical Contamination and Extension of the Oil-Filter Differential-Pressure Indicator (DPI)
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
3. Job Set-up
Subtask 12-13-24-861-057-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 12-13-24-941-063-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to start the engine.
   (2) Make sure that the engine shutdown occurred five minutes or more before you do this procedure.
   (3) On overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 12-13-24-010-060-A ** ON A/C NOT FOR ALL
C. Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 12-13-24-481-054-A ** ON A/C NOT FOR ALL
D. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
4. Procedure
Subtask 12-13-24-864-059-A ** ON A/C NOT FOR ALL
A. Depressurization of the IDG Case
   (1) Let the IDG temperature decrease to120 DEG.F (49 DEG.C) or less before you drain the oil.
WARNING: POINT THE OVERFLOW DRAIN HOSE INTO A CONTAINER WHEN YOU CONNECT THE HOSE TO THE OVERFLOW DRAIN HALF-COUPLING. THIS WILL PREVENT BURNS FROM THE HOT OIL SPRAY. HOT OIL CAN CAUSE BURNS TO EYES AND SKIN.
CAUTION: DO NOT USE DEVICES OTHER THAN THE APPROVED OVERFLOW DRAIN-HOSE FITTING. HARD METAL OBJECTS SUCH AS SCREWDRIVERS CAN CAUSE DAMAGE TO THE OVERFLOW DRAIN HALF-COUPLING SEAT.
CAUTION: MAKE SURE YOU CONNECT THE HOSE OF THE OVERFLOW DRAIN HALF- COUPLING CORRECTLY. THIS HOSE LETS THE OIL IN THE IDG DRAIN TO THE CORRECT LEVEL. IF THERE IS TOO MUCH OIL IN THE IDG THE IDG WILL BECOME TOO HOT.
   (2) Put the CONTAINER 10 L(2 1/2 USGAL) below the IDG (1).
   (3) Remove the dust cap (5) from the overflow drain half-coupling (7).
   (4) Put the end of the overflow drain hose (6) of the FILLING EQUIPMENT - TANK OIL in the CONTAINER 10 L(2 1/2 USGAL).
   (5) Do this step to depressurize the IDG case:
     (a) Connect the overflow drain hose (6) of the FILLING EQUIPMENT - TANK OIL to the overflow drain half-coupling (7).
NOTE: Some oil can come out of the overflow drain hose (6) of the FILLING EQUIPMENT - TANK OIL when you connect it.
Subtask 12-13-24-680-059-E ** ON A/C NOT FOR ALL
B. Draining of the IDG Oil
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (1) Cut and discard the lockwire from the case drain plug (9).
NOTE: Approximately 5.73 l (1.5137 USgal) of oil will flow into the CONTAINER 10 L(2 1/2 USGAL).
   (2) Remove the case drain plug (9).
   (3) Remove and discard the O-ring (8).
   (4) Drain the oil:
     (a) Do the servicing of the IDG (1) after oil chemical contamination (Ref. AMM TASK 24-21-00-612-043) if:
  • You smell fuel from the drained oil.
  • The oil condition is unsatisfactory.
   (5) Remove the dust cap (3) from the pressure fill half-coupling (2).
   (6) Connect the pressure fill hose (4) of the FILLING EQUIPMENT - TANK OIL to the pressure fill half-coupling (2).
   (7) Use the FILLING EQUIPMENT - TANK OIL to fill the IDG (1) with new Synthetic base Lubricating Oil-Turbine Engine - - (Material No.03ABA1) and drain the used oil:
     (a) Make sure that the filling pressure is not more than 2.41 bar (34.95 psi).
   (8) Continue to fill the IDG (1) with new Synthetic base Lubricating Oil-Turbine Engine - - (Material No.03ABA1) until a minimum of 1.85 l (0.49 USgal) of oil flows out of the case drain.
   (9) Stop the FILLING EQUIPMENT - TANK OIL.
   (10) Let the oil drain from the case drain until the flow of oil decreases to drops.
   (11) Disconnect the pressure fill hose (4) of the FILLING EQUIPMENT - TANK OIL from the pressure fill half-coupling (2).
   (12) Install the dust cap (3) on the pressure fill half-coupling (2).
Subtask 12-13-24-640-053-A ** ON A/C NOT FOR ALL Subtask 12-13-24-420-059-A ** ON A/C NOT FOR ALL
D. Installation of the Case Drain Plug
   (1) Install the new O-ring (8) on the case drain plug (9).
   (2) Install the case drain plug (9).
   (3) TORQUE the case drain plug (9) to between 75 and 55 lbf.in (0.85 and 0.62 m.daN ) T.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (4) Safety the case drain plug (9) with the CP8001lockwire 0.032 in. (0.8 mm) dia. 0.032 in. (0.8128 mm).
Subtask 12-13-24-420-065-A ** ON A/C NOT FOR ALL
E. Installation of the Dust Cap
   (1) Remove the overflow drain hose (6) of the FILLING EQUIPMENT - TANK OIL from the overflow drain half-coupling (7).
   (2) Install the dust cap (5) on the overflow drain half-coupling (7).
5. Close-up
Subtask 12-13-24-440-051-A ** ON A/C NOT FOR ALL
Subtask 12-13-24-410-062-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the WARNING NOTICE(S).
Subtask 12-13-24-862-057-A ** ON A/C NOT FOR ALL
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 22:55:00 UTC