W DOC AIRBUS | AMM A320F

General Visual Inspection of Aft Emergency Exit (EWIS)


TASK 05-28-30-200-806-A
General Visual Inspection of Aft Emergency Exit (EWIS)


ZONE: 835
ZONE: 845
1. Reason for the Job
Refer to the MPD TASK: ZL-835-02
GENERAL VISUAL INSPECTION OF AFT EMERGENCY EXIT (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
835
MID PASSENGER/CREW DOOR
845
MID PASSENGER/CREW DOOR
835, 835CZ, 835DZ, 835EZ, 835FZ, 835GZ, 835HZ, 845, 845CZ, 845DZ, 845EZ, 845FZ, 845GZ, 845HZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-47-000-010-A
Removal of the Door Frame Linings of the Left/Right Aft Emergency Exit Doors from Zones 251/252
TASK 25-23-47-400-010-A
Installation of the Door Frame Linings of the Left/Right Aft Emergency Exit Doors in Zones 251/252
TASK 52-22-00-010-002-A
Opening of the Emergency Exit Doors from the Outside
TASK 52-22-00-410-002-A
Closing of the Emergency Exit Doors from the Outside
3. Job Set-up
Subtask 05-28-30-010-067-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 835 (845).
   (2) Open aft emergency-exit door 835 ( 845) (Ref. AMM TASK 52-22-00-010-002).
   (3) Remove aft-emergency-exit door panels 835CZ ( 845CZ), 835DZ ( 845DZ), 835EZ ( 845EZ), 835FZ ( 845FZ), 835GZ ( 845GZ) and 835HZ ( 845HZ) (Ref. AMM TASK 25-23-47-000-010).
   (4) Lift the insulation blanket.
4. Procedure
Subtask 05-28-30-210-072-A ** ON A/C NOT FOR ALL
A. Inspection
F Aft Emergency-Exit Door ** ON A/C NOT FOR ALL
   (1) Do a general visual inspection of the aft-emergency exit doors.
   (2) Make sure that there are no signs of corrosion, cracks or damage.
   (3) Make sure that all the installations (wiring) are attached correctly.
5. Close-up
Subtask 05-28-30-410-067-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Put the insulation blanket back in position.
   (2) Install aft-emergency-exit door panels 835CZ ( 845CZ), 835DZ ( 845DZ), 835EZ ( 845EZ), 835FZ ( 845FZ), 835GZ ( 845GZ) and 835HZ ( 845HZ) (Ref. AMM TASK 25-23-47-400-010).
   (3) Close aft emergency-exit door 835 ( 845) (Ref. AMM TASK 52-22-00-410-002).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 22:51:05 UTC