General Visual Inspection of FWD Avionics Compartment Door (EWIS) (including External Surface)
TASK 05-28-10-200-001-A
General Visual Inspection of FWD Avionics Compartment Door (EWIS) (including External Surface)
Refer to the MPD TASK: ZL-811-01
GENERAL VISUAL INSPECTION OF FWD AVIONICS COMPARTMENT DOOR (EWIS) (INCLUDING EXTERNAL SURFACE)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-28-10-010-050-A
Subtask 05-28-10-210-050-A
Subtask 05-28-10-410-050-A
[Rev.10 from 2021]
2026.03.31 22:50:45 UTC
General Visual Inspection of FWD Avionics Compartment Door (EWIS) (including External Surface)
ZONE: 811
1. Reason for the JobRefer to the MPD TASK: ZL-811-01
GENERAL VISUAL INSPECTION OF FWD AVIONICS COMPARTMENT DOOR (EWIS) (INCLUDING EXTERNAL SURFACE)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 811 | FORWARD AVIONICS COMPARTMENT DOOR |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 05-28-10-010-050-A
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 811.
(2) Open forward avionics compartment door 811 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 811.
(2) Open forward avionics compartment door 811 (Ref. AMM TASK 52-41-00-010-002).
Subtask 05-28-10-210-050-A
A. Inspection
(1) Do a general visual inspection of the forward avionics compartment door. This inspection includes the external surface of the door.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting and piping) are correctly attached.
5. Close-up(1) Do a general visual inspection of the forward avionics compartment door. This inspection includes the external surface of the door.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting and piping) are correctly attached.
Subtask 05-28-10-410-050-A
A. Close Access
(1) Close forward avionics compartment door 811 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the access platform(s).
(1) Close forward avionics compartment door 811 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the access platform(s).