General Visual Inspection of Wing Tip (EWIS)
TASK 05-25-30-200-004-A
General Visual Inspection of Wing Tip (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-534-01
GENERAL VISUAL INSPECTION OF WING TIP (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-25-30-010-053-B ** ON A/C NOT FOR ALL
Subtask 05-25-30-210-053-A
Subtask 05-25-30-410-053-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 22:50:14 UTC
General Visual Inspection of Wing Tip (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-534-01
GENERAL VISUAL INSPECTION OF WING TIP (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT) |
| No specific | 1 | ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 534 | WING TIP |
| 634 | WING TIP |
| 534BB, 534CB, 534DB, 634BB, 634CB, 634DB | |
| 534AB, 534AL, 534BL, 634AB, 634AR, 634BR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 57-31-22-000-001-A | Removal of the Wing-Tip Fence |
| TASK 57-31-22-400-001-A | Installation of the Wing-Tip Fence |
| TASK 57-31-23-000-802-A | Removal of the Sharklet Access Panels |
| TASK 57-31-23-400-802-A | Installation of the Sharklet Access Panels |
Subtask 05-25-30-010-053-B ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position.
(2) Remove the access panels:
- 534AB ( 634AB).
- 534AL ( 634AR) and 534BL ( 634BR)
Subtask 05-25-30-010-053-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT) in position.
(2) Remove the access panels:
- 534AB ( 634AB).
- 534AL ( 634AR) and 534BL ( 634BR)
A. Get Access
(1) Put the ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position.
(2) Remove the access panels:
- 534BB ( 634BB), 534CB ( 634CB) and 534DB ( 634DB) (Ref. AMM TASK 57-31-23-000-802).
4. Procedure(1) Put the ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position.
(2) Remove the access panels:
- 534BB ( 634BB), 534CB ( 634CB) and 534DB ( 634DB) (Ref. AMM TASK 57-31-23-000-802).
Subtask 05-25-30-210-053-A
A. Inspection
(1) Do a general visual inspection of the wing tip.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring) are attached correctly.
5. Close-up(1) Do a general visual inspection of the wing tip.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring) are attached correctly.
Subtask 05-25-30-410-053-B ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the access panels:
- 534AB ( 634AB).
- 534AL ( 634AR) and 534BL ( 634BR) (Ref. AMM TASK 57-31-22-400-001).
(2) Remove the access platform(s).
Subtask 05-25-30-410-053-C ** ON A/C NOT FOR ALL (1) Install the access panels:
- 534AB ( 634AB).
- 534AL ( 634AR) and 534BL ( 634BR) (Ref. AMM TASK 57-31-22-400-001).
(2) Remove the access platform(s).
Access Panels of the Wing Tip