GENERAL VISUAL INSPECTION OF CENTER WING BOX (EWIS)
TASK 05-21-40-200-001-A
GENERAL VISUAL INSPECTION OF CENTER WING BOX (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-141-01
GENERAL VISUAL INSPECTION OF CENTER WING BOX (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-21-40-010-050-A
Subtask 05-21-40-210-050-A
Subtask 05-21-40-410-050-A
[Rev.10 from 2021]
2026.03.31 22:48:44 UTC
GENERAL VISUAL INSPECTION OF CENTER WING BOX (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-141-01
GENERAL VISUAL INSPECTION OF CENTER WING BOX (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 141 | WING CENTER BOX |
| 142 | WING CENTER BOX |
| 147AZ, 148AZ |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 57-17-11-000-001-A | Removal of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-000-001-B | Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door |
| TASK 57-17-11-400-001-A | Installation of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-400-001-B | Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door |
Subtask 05-21-40-010-050-A
A. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zones 141 and 142.
(2) Remove the cover panels:
147AZ 148AZ, (Ref. AMM TASK 57-17-11-000-001).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zones 141 and 142.
(2) Remove the cover panels:
147AZ 148AZ, (Ref. AMM TASK 57-17-11-000-001).
Subtask 05-21-40-210-050-A
A. Inspection
(1) Do a general visual inspection of the wing center box (Zones 141 and 142).
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
5. Close-up(1) Do a general visual inspection of the wing center box (Zones 141 and 142).
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
Subtask 05-21-40-410-050-A
A. Close Access
(1) Install the cover panels:
147AZ 148AZ, (Ref. AMM TASK 57-17-11-400-001).
(2) Remove the access platform(s).
(1) Install the cover panels:
147AZ 148AZ, (Ref. AMM TASK 57-17-11-400-001).