Fault of the Sensor Monitoring at the BULK Cargo-Compartment Door
TASK 52-33-00-810-801-A
Fault of the Sensor Monitoring at the BULK Cargo-Compartment Door
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 52-33-00-710-050-A ** ON A/C NOT FOR ALL
Subtask 52-33-00-810-050-A ** ON A/C NOT FOR ALL
Subtask 52-33-00-860-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:51 UTC
Fault of the Sensor Monitoring at the BULK Cargo-Compartment Door
1. Possible Causes
- PROX SW-FRAME, BULK CARGO COMPT DOOR [50WV]
- wiring
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
- C/B-EIS/SDAC1 AND 2/DOOR/DET/AVNCS [46WV]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-54-00-810-803-A | Failure of the SDAC 2 |
| TSM TASK 31-54-00-810-810-A | Failure of the SDAC 1 |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| ASM 315405 | |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 52-30-00-860-001 | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| AMM 52-30-00-860-008 | Close the Bulk Cargo-Compartment Door |
| AMM 52-71-12-000-003 | Removal of the Proximity Switch |
| AMM 52-71-12-400-003 | Installation of the Proximity Switch |
Subtask 52-33-00-710-050-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) Open and close the BULK Cargo-Compartment Door (referred to as cargo door) AMM 52-30-00-860-001 and AMM 52-30-00-860-008.
(3) On the DOOR/OXY page of the lower ECAM DU, look for possible fault indications.
4. Fault Isolation(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) Open and close the BULK Cargo-Compartment Door (referred to as cargo door) AMM 52-30-00-860-001 and AMM 52-30-00-860-008.
(3) On the DOOR/OXY page of the lower ECAM DU, look for possible fault indications.
Subtask 52-33-00-810-050-A ** ON A/C NOT FOR ALL
A. When the BULK door is closed and the door page of the lower ECAM DU shows the symbol for the BULK door and the message BULK in amber:
do a trouble shooting of the SDAC-1 [1WV1] or SDAC-2 [1WV2] (Ref. TSM TASK 31-54-00-810-810) or (Ref. TSM TASK 31-54-00-810-803).
Subtask 52-33-00-710-051-A ** ON A/C NOT FOR ALL - make sure that the adjustment of the PROX SW-FRAME, BULK CARGO COMPT DOOR [50WV] is correct AMM 52-71-12-400-003.
- install the jumper wire between the:
PROX SW-FRAME, BULK CARGO COMPT DOOR [50WV] connectors A/B and A/C ASM 315405.
- replace the PROX SW-FRAME, BULK CARGO COMPT DOOR [50WV] AMM 52-71-12-000-003 and AMM 52-71-12-400-003.
- do a check for 28 VDC between the:
PROX SW-FRAME, BULK CARGO COMPT DOOR [50WV] connectors A/A and A/D ASM 315405.
- do a check and repair the wiring between:
PROX SW-FRAME, BULK CARGO COMPT DOOR [50WV] connector A/B and SDAC-1 [1WV1] or SDAC-2 [1WV2] connector AD/12D ASM 315405.
- do a check and repair the wiring between the:
PROX SW-FRAME, BULK CARGO COMPT DOOR [50WV] connector A/A and the C/B-EIS/SDAC1 AND 2/DOOR/DET/AVNCS [46WV] ASM 315405.
do a trouble shooting of the SDAC-1 [1WV1] or SDAC-2 [1WV2] (Ref. TSM TASK 31-54-00-810-810) or (Ref. TSM TASK 31-54-00-810-803).
B. Do the test as given in Para. 3.A. to make sure that the operation is correct.
5. Close-upSubtask 52-33-00-860-050-A ** ON A/C NOT FOR ALL