Failure of the SDAC 2


TASK 31-54-00-810-803-A
Failure of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • wiring from the SDAC 2 (1WV2) pin AC/1 to the circuit breaker (2WV)
  • C/B-EIS/SDAC/2/SPLY [2WV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315101
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-054-A
A. Test
Do the ground scanning of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-865-143-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUEIS/SDAC/2/SPLY2WVQ06
Subtask 31-54-00-810-058-A
B. If the test gives the maintenance message:
SDAC2
  • do a check of the status of the circuit breaker (2WV).
   (1) If the circuit breaker (2WV) is closed:
     (a) If the fault continues:
  • do a check of the wiring from the SDAC 2 (1WV2) pin AC/1 to the circuit breaker (2WV), ASM 315101.
       1 If there is no continuity:
  • repair the wiring given above.
       2 If there is continuity:
  • replace the C/B-EIS/SDAC/2/SPLY [2WV] .
   (2) If the circuit breaker (2WV) is open:
  • close the circuit breaker.
     (a) If the circuit breaker is open again:
  • replace the SDAC-2 [1WV2] .
       1 If the fault continues:
  • do a check and repair for a short to ground the wiring between the circuit breaker (2WV) and the SDAC 2 (1WV2).
     (b) If the circuit breaker stays closed and the fault continues:
  • replace the SDAC-2 [1WV2] .
Subtask 31-54-00-710-055-A
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:40:41 UTC