Failure of the SDAC 1
TASK 31-54-00-810-810-A
Failure of the SDAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-068-A 4. Fault Isolation
Subtask 31-54-00-865-142-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:00 UTC
Failure of the SDAC 1
1. Possible Causes
- SDAC-1 [1WV1]
wiring from the SDAC 1 (1WV1) pin AC/1 to the circuit breaker (3WV) - C/B-SDAC/1/SPLY [3WV]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315101 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-068-A 4. Fault Isolation
Subtask 31-54-00-865-142-A
A. Table of the circuit breakers used in this procedure:
Subtask 31-54-00-810-065-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | SDAC/1/SPLY | 3WV | F04 |
B. If the test gives the maintenance message:
SDAC1
Subtask 31-54-00-710-069-A SDAC1
- do a check of the status of the circuit breaker (3WV).
- replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check of the
wiring from the SDAC 1 (1WV1) pin AC/1 to the circuit breaker (3WV) , ASM 315101.
- repair the wiring given above.
- replace the C/B-SDAC/1/SPLY [3WV] .
- close the circuit breaker.
- replace the SDAC-1 [1WV1] .
- do a check and repair for a short to ground the wiring between the circuit breaker (3WV) and the SDAC 1 (1WV1).
- replace the SDAC-1 [1WV1] .
C. Do the test given in Para. 3.