W DOC AIRBUS | TSM A320F

Failure of the SDAC 1


TASK 31-54-00-810-810-A
Failure of the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • wiring from the SDAC 1 (1WV1) pin AC/1 to the circuit breaker (3WV)
  • C/B-SDAC/1/SPLY [3WV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315101
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-068-A
A. Test
Do the ground scanning of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-865-142-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUSDAC/1/SPLY3WVF04
Subtask 31-54-00-810-065-A
B. If the test gives the maintenance message:
SDAC1
  • do a check of the status of the circuit breaker (3WV).
   (1) If the circuit breaker (3WV) is closed:
     (a) If the fault continues:
  • do a check of the wiring from the SDAC 1 (1WV1) pin AC/1 to the circuit breaker (3WV), ASM 315101.
       1 If there is no continuity:
  • repair the wiring given above.
       2 If there is continuity:
  • replace the C/B-SDAC/1/SPLY [3WV] .
   (2) If the circuit breaker (3WV) is open:
  • close the circuit breaker.
     (a) If the circuit breaker is open again:
  • replace the SDAC-1 [1WV1] .
       1 If the fault continues:
  • do a check and repair for a short to ground the wiring between the circuit breaker (3WV) and the SDAC 1 (1WV1).
     (b) If the circuit breaker stays closed and the fault continues:
  • replace the SDAC-1 [1WV1] .
Subtask 31-54-00-710-069-A
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:39:00 UTC