W DOC AIRBUS | TSM A320F

Sensor Monitoring Fault at the LH FWD Passenger Compartment Emergency Exit


TASK 52-21-00-810-801-A
Sensor Monitoring Fault at the LH FWD Passenger Compartment Emergency Exit


1. Possible Causes
  • PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1]
  • wiring
  • IND LT-SLIDE ARMED, L EMER EXIT [2WN1]
  • PROX SW-HANDLE FLAP, L AFT EMER EXIT [21WV1]
  • SDAC-1 [1WV1]
  • SDAC-2 [1WV2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-54-00-810-803-A
Failure of the SDAC 2
TSM TASK 31-54-00-810-810-A
Failure of the SDAC 1
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 25-23-47-000-001
Removal of the Lining from the Emergency Exit Hatches
AMM 25-23-47-400-001
Installation of the Lining on the Emergency Exit Hatches
ASM 315405
AMM 31-60-00-860-001
EIS Start Procedure
AMM 52-71-13-000-001
Removal of the Proximity Switches
AMM 52-71-13-400-001
Installation of the Proximity Switches
ASM 527301
AMM 52-73-21-000-003
Removal of the SLIDE ARMED Indicator-Light of the Emergency Exit
AMM 52-73-21-400-003
Installation of the SLIDE ARMED Indicator-Light of the Emergency Exit
3. Fault Confirmation
Subtask 52-21-00-865-052-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
Subtask 52-21-00-710-050-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001
   (2) Remove and install the cover flap of the LH-FWD emergency-exit hatch (referred to as the hatch) AMM 25-23-47-000-001 and AMM 25-23-47-400-001.
NOTE: This makes sure that the target bracket of the cover flap is in its correct installation position.
   (3) On the DOOR/OXY page of the lower ECAM DU, look for the possible fault indication.
4. Fault Isolation
Subtask 52-21-00-810-050-A ** ON A/C NOT FOR ALL
A. When the cover flap is correctly installed and the DOOR/OXY page of the lower ECAM DU shows the symbol for the hatch and the message EMER EXIT in amber:
   (1) If the fault continues:
  • installthe jumper wire between the:
    PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connectors A/C and A/B ASM 315405.
     (a) If the message EMER EXIT goes off and the symbol for the hatch changes to green:
     (b) If the message EMER EXIT remains on in amber:
  • do a check for 28 VDC between the:
    PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connectors A/A and A/C ASM 315405.
       1 If there is 28 VDC:
  • do a check and repair the wiring between:
    the PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connector A/B and the IND LT-SLIDE ARMED, L EMER EXIT [2WN1] connector A/E ASM 315405.
       2 If there is no 28 VDC:
  • do a check and repair the wiring between the:
    PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connector A/A and the IND LT-SLIDE ARMED, L EMER EXIT [2WN1] connector A/R ASM 315405.
    PROX SW-HANDLE FLAP, L AFT EMER EXIT [21WV1] connector A/C and ground ASM 315405.
   (2) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between:
    the IND LT-SLIDE ARMED, L EMER EXIT [2WN1] connector A/G and the SDAC-1 [1WV1] or SDAC-2 [1WV2] connector AA/11C ASM 527301 .
       1 If the fault continues:
do the trouble shooting procedure of the SDAC-1 [1WV1] or SDAC-2 [1WV2] (Ref. TSM TASK 31-54-00-810-803) or (Ref. TSM TASK 31-54-00-810-810).
Subtask 52-21-00-710-054-A ** ON A/C NOT FOR ALL
B. Test
   (1) On the ECAM control panel:
  • push the DOOR key to get the DOOR/OXY page.
   (2) Make sure that the latch pin for both LH emergency exits is in the slide armed position.
   (3) Make sure that the SLIDE indication is shown on the DOOR/OXY page.
NOTE: If this occurs, the trouble shooting procedure is correct.
5. Close-up
Subtask 52-21-00-860-050-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:34:48 UTC