Sensor Monitoring Fault at the LH FWD Passenger Compartment Emergency Exit
TASK 52-21-00-810-801-A
Sensor Monitoring Fault at the LH FWD Passenger Compartment Emergency Exit
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 52-21-00-865-052-A ** ON A/C NOT FOR ALL
Subtask 52-21-00-810-050-A ** ON A/C NOT FOR ALL
Subtask 52-21-00-860-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:48 UTC
Sensor Monitoring Fault at the LH FWD Passenger Compartment Emergency Exit
1. Possible Causes
- PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1]
- wiring
- IND LT-SLIDE ARMED, L EMER EXIT [2WN1]
- PROX SW-HANDLE FLAP, L AFT EMER EXIT [21WV1]
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-54-00-810-803-A | Failure of the SDAC 2 |
| TSM TASK 31-54-00-810-810-A | Failure of the SDAC 1 |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 25-23-47-000-001 | Removal of the Lining from the Emergency Exit Hatches |
| AMM 25-23-47-400-001 | Installation of the Lining on the Emergency Exit Hatches |
| ASM 315405 | |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 52-71-13-000-001 | Removal of the Proximity Switches |
| AMM 52-71-13-400-001 | Installation of the Proximity Switches |
| ASM 527301 | |
| AMM 52-73-21-000-003 | Removal of the SLIDE ARMED Indicator-Light of the Emergency Exit |
| AMM 52-73-21-400-003 | Installation of the SLIDE ARMED Indicator-Light of the Emergency Exit |
Subtask 52-21-00-865-052-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 52-21-00-710-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
B. Test
(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001
(2) Remove and install the cover flap of the LH-FWD emergency-exit hatch (referred to as the hatch) AMM 25-23-47-000-001 and AMM 25-23-47-400-001.
4. Fault Isolation(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001
(2) Remove and install the cover flap of the LH-FWD emergency-exit hatch (referred to as the hatch) AMM 25-23-47-000-001 and AMM 25-23-47-400-001.
NOTE: This makes sure that the target bracket of the cover flap is in its correct installation position.
(3) On the DOOR/OXY page of the lower ECAM DU, look for the possible fault indication. Subtask 52-21-00-810-050-A ** ON A/C NOT FOR ALL
A. When the cover flap is correctly installed and the DOOR/OXY page of the lower ECAM DU shows the symbol for the hatch and the message EMER EXIT in amber:
do the trouble shooting procedure of the SDAC-1 [1WV1] or SDAC-2 [1WV2] (Ref. TSM TASK 31-54-00-810-803) or (Ref. TSM TASK 31-54-00-810-810).
Subtask 52-21-00-710-054-A ** ON A/C NOT FOR ALL - make sure that the adjustment of the PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] is correct AMM 52-71-13-400-001.
- installthe jumper wire between the:
PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connectors A/C and A/B ASM 315405.
- replace the PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] AMM 52-71-13-000-001 and AMM 52-71-13-400-001.
- do a check for 28 VDC between the:
PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connectors A/A and A/C ASM 315405.
- do a check and repair the wiring between:
the PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connector A/B and the IND LT-SLIDE ARMED, L EMER EXIT [2WN1] connector A/E ASM 315405.
- do a check and repair the wiring between the:
PROX SW-HANDLE FLAP, L FWD EMER EXIT [19WV1] connector A/A and the IND LT-SLIDE ARMED, L EMER EXIT [2WN1] connector A/R ASM 315405.
PROX SW-HANDLE FLAP, L AFT EMER EXIT [21WV1] connector A/C and ground ASM 315405.
- replace the IND LT-SLIDE ARMED, L EMER EXIT [2WN1] AMM 52-73-21-000-003 and AMM 52-73-21-400-003.
- do a check and repair the wiring between:
the IND LT-SLIDE ARMED, L EMER EXIT [2WN1] connector A/G and the SDAC-1 [1WV1] or SDAC-2 [1WV2] connector AA/11C ASM 527301 .
do the trouble shooting procedure of the SDAC-1 [1WV1] or SDAC-2 [1WV2] (Ref. TSM TASK 31-54-00-810-803) or (Ref. TSM TASK 31-54-00-810-810).
B. Test
(1) On the ECAM control panel:
(3) Make sure that the SLIDE indication is shown on the DOOR/OXY page.
5. Close-up(1) On the ECAM control panel:
- push the DOOR key to get the DOOR/OXY page.
(3) Make sure that the SLIDE indication is shown on the DOOR/OXY page.
NOTE: If this occurs, the trouble shooting procedure is correct.
Subtask 52-21-00-860-050-A ** ON A/C NOT FOR ALL