LIQUID LVL SNSR OR LIQUID LVL XMTR OR VAC SYS CONT Fault
TASK 38-31-00-810-822-A
LIQUID LVL SNSR OR LIQUID LVL XMTR OR VAC SYS CONT Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-090-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-103-C ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:14 UTC
LIQUID LVL SNSR OR LIQUID LVL XMTR OR VAC SYS CONT Fault
1. Possible Causes
Liquid Level Transmitter (LLT) reference line - WATER SEPERATOR [3302MM]
- GENERATOR,VACUUM [37MG]
- XMTR-LEVEL [40MG]
- SENSOR,LEVEL [41MG]
- CONTROLLER VACUUM SYS [31MG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-818-A | Computer Reset |
| AMM 38-31-00-100-009 | Cleaning of the Liquid Level Transmitter (LLT) Reference Line |
| AMM 38-31-00-710-002 | Operational Test of the Vacuum Toilet System |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-34-000-001 | Removal of the Vacuum System Controller |
| AMM 38-31-34-400-001 | Installation of the Vacuum System Controller |
| AMM 38-31-62-000-001 | Removal of the Liquid Level Transmitter |
| AMM 38-31-62-400-001 | Installation of the Liquid Level Transmitter |
| AMM 38-31-63-000-001 | Removal of the Liquid Level Sensor |
| AMM 38-31-63-400-001 | Installation of the Liquid Level Sensor |
| AMM 38-31-64-000-001 | Removal of the Vacuum Generator |
| AMM 38-31-64-400-001 | Installation of the Vacuum Generator |
| AMM 38-31-67-610-001 | Inspect Water Separator and Associated Filter Element, and Clean as Necessary |
Subtask 38-31-00-710-090-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-103-C ** ON A/C NOT FOR ALL
A. If the operational test operates OK:
LIQD LVL XMTR/
LIQD LVL SNSR/VSC:
Subtask 38-31-00-810-103-F ** ON A/C NOT FOR ALL - Refer to the bite test last leg or previous leg report page.
LIQD LVL XMTR/
LIQD LVL SNSR/VSC:
- do the procedure to reset the VSC (Ref. TSM TASK 24-00-00-810-818).
- do a check and clean the
Liquid Level Transmitter (LLT) reference line AMM 38-31-00-100-009.
- do a check and clean the WATER SEPERATOR [3302MM] as necessary AMM 38-31-67-610-001.
- replace the GENERATOR,VACUUM [37MG] , AMM 38-31-64-000-001 and AMM 38-31-64-400-001.
- replace the XMTR-LEVEL [40MG] , AMM 38-31-62-000-001 and AMM 38-31-62-400-001.
- replace the SENSOR,LEVEL [41MG] , AMM 38-31-63-000-001 and AMM 38-31-63-400-001.
- replace the CONTROLLER VACUUM SYS [31MG] , AMM 38-31-34-000-001 and AMM 38-31-34-400-001.
A. If the operational test operates OK:
LIQUID LVL SNSR OR
LIQUID LVL XMTR OR
VAC SYS CONT:
LIQD LVL XMTR/
LIQD LVL SNSR/VSC:
Subtask 38-31-00-710-091-A ** ON A/C NOT FOR ALL - Refer to the bite test last leg or previous leg report page.
LIQUID LVL SNSR OR
LIQUID LVL XMTR OR
VAC SYS CONT:
NOTE: This is when the VSC with the P/N 14404-001-1 or P/N 14404-11 is installed.
- do the procedure to reset the VSC (Ref. TSM TASK 24-00-00-810-818).
- do a check and clean the
Liquid Level Transmitter (LLT) reference line AMM 38-31-00-100-009.
- do a check and clean the WATER SEPERATOR [3302MM] as necessary AMM 38-31-67-610-001.
- replace the GENERATOR,VACUUM [37MG] , AMM 38-31-64-000-001 and AMM 38-31-64-400-001.
- replace the XMTR-LEVEL [40MG] , AMM 38-31-62-000-001 and AMM 38-31-62-400-001.
- replace the SENSOR,LEVEL [41MG] , AMM 38-31-63-000-001 and AMM 38-31-63-400-001.
- replace the CONTROLLER VACUUM SYS [31MG] , AMM 38-31-34-000-001 and AMM 38-31-34-400-001
LIQD LVL XMTR/
LIQD LVL SNSR/VSC:
NOTE: This is when the VSC with the P/N 14404-011A, P/N 14404-11B or P/N 1404-010 is installed.
- do the procedure to reset the VSC (Ref. TSM TASK 24-00-00-810-818).
- do a check and clean the
Liquid Level Transmitter (LLT) reference line AMM 38-31-00-100-009.
- do a check and clean the WATER SEPERATOR [3302MM] as necessary AMM 38-31-67-610-001.
- replace the GENERATOR,VACUUM [37MG] , AMM 38-31-64-000-001 and AMM 38-31-64-400-001.
- replace the XMTR-LEVEL [40MG] , AMM 38-31-62-000-001 and AMM 38-31-62-400-001.
- replace the SENSOR,LEVEL [41MG] , AMM 38-31-63-000-001 and AMM 38-31-63-400-001.
- replace the CONTROLLER VACUUM SYS [31MG] , AMM 38-31-34-000-001 and AMM 38-31-34-400-001.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.