W DOC AIRBUS | TSM A320F

Computer Reset


TASK 24-00-00-810-818-A
Computer Reset


1. Possible Causes

2. Fault Confirmation
Subtask 24-00-00-710-059-A
A. Test
   (1) Not applicable
3. Fault Isolation
Subtask 24-00-00-865-051-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT/CTL & MONG31HNC07
49VUAIR COND/AFT CARGO/VENT/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/SDCU/CHAN111WQC06
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DIR ESS/2157RHG02
** ON A/C ALL
49VUFUEL/FQI/CHAN/11QTA13
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B11
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B10
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B08
49VUAUTO FLT/FCU/19CA1B05
49VUAUTO FLT/FAC1/28VDC5CC1B04
49VUAUTO FLT/FAC1/26VAC14CC1B03
49VUAUTO FLT/FMGC/110CA1B02
49VUAUTO FLT/MCDU/111CA1B01
49VUL/G/LGCIU/SYS1/NORM1GAC09
49VUAIR COND/CAB/PRESS/CTL11HLD09
49VUEIS/DMC1/SPLY10WT1E11
49VUFWS/FWC1/SPLY3WWF01
49VUNAV/MMR/142RT1G12
49VUCOM/CIDS/DIR ESS/1150RHG01
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT & HTG/CTL & MONG31HNC07
49VUAIR COND/AFT CARGO/VENT & HTG/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
49VUCOM/CIDS/FLT ATTND PNL/ESS171RHH01
** ON A/C NOT FOR ALL
49VUCOM DIR ESS/2157RHG02
** ON A/C NOT FOR ALL
121VUCOM NAV/MMR/242RT2K09
** ON A/C NOT FOR ALL
121VUCOM /CIDS/FWD ATTND/PNL170RHQ14
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/PROG &/TST PNL161RHM07
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2/EVMU1EVR44
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DIR NORM/2156RHM06
121VUCOM NAV/CIDS/DIR NORM/1151RHM05
** ON A/C ALL
121VUCOM NAV/RAD ALTM/21SA2K12
121VUCOM NAV/RAD ALTM/11SA1K11
121VUCOM NAV/TCAS4SGK10
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUFUEL/FQI/CHANNEL/1 AND 28QTL26
121VUATSU 13TX1L16
121VUATSU 1/SWTG5TX1L15
121VUHYDRAULIC/BRAKING AND STEERING/SYS2/SPLY4GGM36
121VUHYDRAULIC/BRAKING AND STEERING/SYS2/CTL3GGM35
121VUHYDRAULIC/BRAKING AND STEERING/SYS1/CTL1GGM34
121VUHYDRAULIC/BRAKING AND STEERING/SYS1/IND AND/SPLY2GGM33
121VUFUEL/FQI/CHAN/22QTM27
121VUAUTO FLT/FCU/29CA2M21
121VUAUTO FLT/FAC2/28VDC5CC2M19
121VUAUTO FLT/FAC2/26VAC14CC2M18
121VUAUTO FLT/FMGC/210CA2M17
121VUAUTO FLT/MCDU/211CA2N20
121VUEIS/GPWS/115VAC3WZP07
121VUENGINE/ENG2/FADEC B/AND EIU 24KS2Q40
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
121VUFLIGHT CONTROLS/FCDC2/SPLY20CE2Q20
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
121VUEIS/DMC3/SPLY10WT3Q09
121VUEIS/DMC2/SPLY10WT2Q08
121VUEIS/FWC2/SPLY2WWQ07
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
** ON A/C NOT FOR ALL
121VUCOM NAV/MMR/242RT2L07
** ON A/C NOT FOR ALL
121VUCOM /CIDS/FLT ATTND/PNL170RHQ14
** ON A/C NOT FOR ALL
121VUCOM/FAP1/NORM170RHQ14
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DIR NORM/2156RHM07
121VUCOM NAV/CIDS/DIR NORM/1151RHM06
121VUCOM NAV/CIDS/FWD ATTND/PNL170RHQ14
** ON A/C NOT FOR ALL
122VUAIR COND/SDCU/CHAN212WQT18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS22HKV18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS11HKV17
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C ALL
122VUANTI ICE/WHC/25DG2W13
122VUANTI ICE/WHC/15DG1X13
122VUAIR COND/CAB PRESS/CTL/22HLY22
122VUAIR COND/AVNCS/VENT/MONG3HQY17
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACUUM TOILET SYSTEM/VACUUM SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
Subtask 24-00-00-810-069-A
B. Computer reset procedure
NOTE: This reset procedure is used when a computer does not operate correctly.
NOTE: The line maintenance personnel can use it a first time to avoid a computer replacement (a reset must be done for the applicable computer as indicated in the Computer Reset Table).
But, if there is more than one reset for each flight cycle for a given computer, it is necessary to do the specific troubleshooting procedure for the applicable system.
If after a reset, the computer operates correctly, no more action is necessary.
   (1) To do computer reset:
     (a) Set the related normal cockpit control to OFF, or open the related circuit breaker as specified in the reset procedure.
     (b) Wait 3 seconds if a normal cockpit control is used, or 5 seconds if a circuit breaker is used (unless a different time is indicated).
     (c) Set the related normal cockpit control to ON, or close the related circuit breaker.
     (d) Wait 3 seconds for the end of the reset.
Subtask 24-00-00-810-075-C ** ON A/C NOT FOR ALL
C. Air Conditioning
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
21
CAB PR SYS 1(2) FAULT
CABIN
PRESSURE
CONTROLLER
(CPC) 1(2)
For CPC 1:
- On panel 49VU, open the
circuit breaker 1HL.
FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.
21
COND ZONE REGUL FAULT
ZONE
TEMPERATURE
CONTROLLER
On panel 122VU:
- Open the circuit breaker 1HK.
- Open the circuit breaker 2HK.
After five seconds, close the
circuit breaker.
21
AIR FWD (AFT) CRG VENT
FAULT
CARGO
VENTILATION
CONTROLLER
On panel 49VU:
- Open the circuit breaker 31HN.
After five seconds, close the
circuit breaker.
21
VENT AVNCS SYS FAULT
AVIONICS EQUIPMENT VENTILATION COMPUTER
On panel 122VU:
- Open the circuit breaker 3HQ.
After five seconds, close the
circuit breaker.
21
AIR PACK 1(2) REGUL FAULT
PACK
CONTROLLER
(PC) 1(2)
For the PC 1:
- On panel 122VU, open
then close the circuit breaker 2HH.
For the PC 2:
- On panel 122VU, open
then close the circuit breaker 22HH.
21
COND AFT CRG HEAT FAULT
AFT CARGO
HEAT
CONTROLLER
On panel 49VU:
- Open the circuit breaker 31HN.
- After five seconds, close the
circuit breaker.
Subtask 24-00-00-810-075-E ** ON A/C NOT FOR ALL
C. Air Conditioning
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
21
CAB PR SYS 1(2) FAULT
CABIN
PRESSURE
CONTROLLER
(CPC) 1(2)
For CPC 1:
- On panel 49VU, open the
circuit breaker 1HL.
FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.
21
AIR FWD (AFT) CRG VENT
FAULT
CARGO
VENTILATION
CONTROLLER
On panel 49VU:
- Open the circuit breaker 31HN
After five seconds, close the
circuit breaker.
21
VENT AVNCS SYS FAULT
AVIONICS EQUIPMENT VENTILATION COMPUTER
On panel 122VU:
- Open the circuit breaker 3HQ.
After five seconds, close the
circuit breaker.
21
AIR PACK 1(2) REGUL FAULT
AIR COND
SYSTEM
CONTROLLER
(ACSC) 1(2)
For the ACSC 1:
- On panel 122VU, open
the circuit breaker 49HH,
circuit breaker 50HH
and circuit breaker 51HH.
- On panel 49VU, open
the circuit breaker 52HH.
Then close the circuit breakers.
For the ACSC2:
- On panel 122VU, open
the circuit breaker 53HH,
circuit breaker 54HH,
circuit breaker 55HH and
circuit breaker 56HH.
Then close the circuit breakers.
21
COND AFT CRG HEAT FAULT
AFT CARGO
HEAT
CONTROLLER
On panel 49VU:
- Open the circuit breaker 31HN.
- After five seconds, close
the circuit breaker.
Subtask 24-00-00-810-076-A
D. Auto Flight
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
22
AUTO FLT YAW DAMPER 1(2)
FAULT
FAC1(2)
Open these C/Bs with the
Yellow and Green hydraulic
systems pressurized:
- for the FAC 1: on the
panel 49VU, C/B 5CC1
- for the FAC 2: on the
panel 121VU, C/B 5CC2
Then close the C/Bs after 10
seconds.
22
WINDSHEAR DET FAULT or
REAC W/S DET FAULT
FAC 1+2
Open then close the C/Bs in
this the order:
- on the panel 49VU, C/B
5CC1 and C/B 14CC1
- on the panel 121VU, C/B
5CC2 and C/B 14CC2.
22
AUTO FLT FCU 1(2) FAULT
FCU
For the FCU1:
- on the panel 49VU, open
the C/B 9CA1.
For the FCU2:
- on the panel 121VU, open
the C/B 9CA2.
Close the C/B after 5
seconds.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful).
If the fault continues, open
again the two C/Bs 9CA1
on 49VU and 9CA2 on 121VU.
Close the C/Bs after 7 min,
with an interval less than
5 sec between side 1 and
side 2.
At least 30 sec are necessary
until the end of the FCU1
and FCU2 safety test.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful)
If the fault continues, end
of procedure (reset
unsuccessful).
22
One MCDU locked or blank
MCDU
Open then close the C/B of
the defective MCDU after 10
seconds:
- For the MCDU1: on the
panel 121VU or panel 49VU,
C/B 11CA1.
- For the MCDU2: on the
panel 121VU, C/B 11CA2.
- For the MCDU3: on the
panel 121VU, C/B 11CA3.
22
FMGC malfunction
Both MCDUs locked or blank
FMGC
FMGC
On the panel 121VU or 49VU:
- open the FMGC 1 C/B 10CA1
and close it after 10
seconds.
When initiated engine
stopped
(aircraft in maintenance
configuration), the reset
will be followed by a
power-up test sequence of
around 90 seconds. During
this test sequence,
the system is unavailable.
If there is no reset of the
FMGC 1, do a reset of the
FMGC 2 on the panel 121VU:
- open the C/B 10CA2 and
close it after 10 seconds.
Subtask 24-00-00-810-077-B ** ON A/C NOT FOR ALL
E. Communications
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
23
COM CIDS 1+2 FAULT
CIDS
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23
Uncommanded EVAC horn
actuation
CIDS
Press the EVAC/HORN SHUT
OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23
Frozen RMP
RMP
You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.
23
Frozen FAP
FAP or
Tape
reproducer/
PRAM
On the panel 121VU, Open
the FAP C/B 170RH.
- After 10 seconds, close
the C/B 170RH.
If unsuccessful:
on the panel 2000VU
- open the tape reproducer
/PRAM C/B 2RX.
After 10 seconds, close the
C/B.
Subtask 24-00-00-810-077-C ** ON A/C NOT FOR ALL
E. Communications
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
23
COM CIDS 1+2 FAULT
CIDS
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.
23
Uncommanded EVAC horn
actuation
CIDS
Press the EVAC/HORN SHUT
OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.
23
Frozen RMP
RMP
You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.
23
Frozen FAP
Tape
reproducer
Open the C/Bs in this order:
On the panel 49VU, CB 171RH
On the panel 121VU, CB
170RH
- After 10 seconds, close
the C/Bs in this order:
170RH, 171RH
If unsuccessful:
on the panel 2000VU
- open the tape reproducer
/PRAM C/B 2RX.
After 10 seconds, close the
C/B.
Subtask 24-00-00-810-077-D ** ON A/C NOT FOR ALL
E. Communications
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
23
COM CIDS 1+2 FAULT
CIDS
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23
Uncommanded EVAC horn
actuation
CIDS
Press the EVAC/HORN SHUT
OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23
Frozen RMP
RMP
You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.
23
Frozen FAP
FAP
Open the C/Bs in this order:
On the panel 49VU, CB 171RH
On the panel 121VU, CB
170RH
- After 10 seconds, close
the C/Bs in this order:
170RH, 171RH
If unsuccessful:
on the panel 2000VU
- open the tape reproducer
/PRAM C/B 2RX.
After 10 seconds, close the
C/B.
Subtask 24-00-00-810-088-A
F. Electrical Power
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
24
GPU cannot be connected
to the aircraft
GAPCU
If at least one power source
(IDG 1 or IDG 2, APU GEN or
batteries) is connected to
the electrical network of
the aircraft:
- On the ELEC control panel
35VU:
. Push and release the
EXT PWR pushbutton
switch.
If no power source is
connected to the electrical
network of the aircraft:
- On the ELEC control panel
35VU:
. Push the BAT 1 and BAT 2
pushbutton switches
(the OFF legend goes
off).
Subtask 24-00-00-810-078-A ** ON A/C NOT FOR ALL
G. Fire Protection
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
26
SMOKE LAV + CRG DET FAULT
SDCU
On the panel 49VU:
- open the C/B 11WQ
On the panel 122VU:
- open the C/B 12WQ
After 10 seconds, close the
two C/B's.
26
ENG1(2) LOOP k FAULT
ENGINE FDU
On the panel 49VU:
- For ENG1 FDU, open the
C/B 7WD1.
- For ENG2 FDU, open the
C/B 8WD2.
On the panel 121VU:
- For ENG1 FDU, open the
C/B 8WD1.
- For ENG2 FDU, open the
C/B 7WD2.
- After 5 seconds, close
the C/Bs.
26
APU FIRE LOOP k FAULT
APU FDU
On the panel 121VU:
- Open the C/Bs 2WG and 1WG.
- After 5 seconds, close the
C/Bs.
Subtask 24-00-00-810-079-A
H. Flight Controls
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
27
F/CTL ELAC 1(2) FAULT
F/CTL ALTN LAW FAULT
ELAC
Reset the defective ELAC:
- Make sure that the
hydraulic systems are
depressurized before the
reset.
- Set the ELAC pushbutton
switch to OFF, then to ON.
27
ELAC or SEC malfunction
ELAC or SEC
Reset the defective ELAC:
- Make sure that the
hydraulic systems are
depressurized before the
reset.
Open, then close the C/B of
the defective ELAC or SEC.
For the ELAC 1(2):
- On the panel 49VU, C/B
15CE1.
- On the panel 121VU, C/B
15CE2.
For the SEC 1(2)(3):
- On the panel 49VU, C/B
21CE1.
- On the panel 121VU, C/B
21CE2 or 21CE3.
27
E/W FCDC1(2) FAULT
FCDC
On the panel 49VU:
- For FCDC1, open the C/B
20CE1.
- For FCDC2, open the C/B
20CE2.
- After 5 seconds, close
the C/Bs.
Subtask 24-00-00-810-089-A ** ON A/C NOT FOR ALL
I. Fuel
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
28
Loss of fuel quantity
indication or,
Simultaneous triggering
of FUEL L XFR VALVE
CLOSED and FUEL R XFR
VALVE CLOSED, although
FUEL SD indicates no
anomaly.
FQIC
On the overhead circuit
breaker panel 49VU:
- Open the C/B 1QT.
On the rear circuit
breaker panel 121VU:
- Open the C/Bs 2QT and 8QT.
After 5 seconds, close the
three C/B's.
Subtask 24-00-00-810-089-B ** ON A/C NOT FOR ALL
I. Fuel
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
28
Loss of fuel quantity indication
FQIC
On the overhead circuit-breaker-panel 49VU:
- Open the circuit-breaker 1QT.
On the rear circuit-breaker-panel 121VU:
- Open the circuit breakers 2QT and 8QT.
After five seconds, close the three circuit breakers.
Subtask 24-00-00-810-080-A
J. Ice and Rain Protection
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
30
ANTI ICE
L(R)/WINSHIELD (WINDOW)
WHC
Open then close the C/B of
the defective WHC.
For the WHC1:
- on the panel 122VU, C/B
5DG1.
For the WHC2:
- on the panel 122VU, C/B
5DG2.
Subtask 24-00-00-810-081-A
K. Indicating/Recording Systems
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
31
FWS FWC 1(2) FAULT
FWC
Open then close the C/B of
the defective FWC
For the FWC1:
- on the panel 49VU, C/B 3WW
For the FWC2:
- on the panel 121VU, C/B
2WW.
Wait 50 seconds after you
close the C/Bs.
31
EIS DMC 1(2)(3) FAULT
DMC
Open then close the
circuit breaker of
the defective DMC
For the DMC1:
- on the overhead C/B panel
49VU, the circuit breaker
10WT1.
For the DMC2:
- on the rear C/B panel
121VU, the circuit breaker
10WT2.
For the DMC3:
- on the rear C/B panel
121VU, the circuit breaker
10WT3.
31
CAPT PFD DU malfunction
CAPT PFD DU
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.
31
CAPT ND DU malfunction
CAPT ND DU
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the ND potentiometer
from the OFF position to
the BRT position.
31
F/O PFD DU malfunction
F/O PFD DU
On the F/O lightning/loud
speaker control-panel 500VU,
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.
31
F/O ND DU malfunction
F/O ND DU
On the F/O lightning/loud
speaker control-panel 500VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the ND potentiometer
from the OFF position to
the BRT position.
31
EWD malfunction
EWD
On the ECAM control panel
turn the UPPER DISPLAY
potentiometer from the
BRT + position to the OFF
position.
- Wait for more than five
seconds.
On the ECAM control panel
turn the UPPER DISPLAY
potentiometer from the
OFF position to the BRT +
position.
31
SD malfunction
SD
On the ECAM control panel
turn the LOWER DISPLAY
potentiometer from the
BRT position to the OFF
position.
- Wait for more than five
seconds.
On the ECAM control panel
turn the LOWER DISPLAY
potentiometer from the
OFF position to the BRT
position.
Subtask 24-00-00-810-082-A
L. Landing Gear
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
32
Braking malfunction
BSCU
On the panel 121VU:
- open the C/Bs 1GG, 2GG,
3GG and 4GG
- after 5 seconds, close
the CB's
32
L/G LGCIU 1(2) FAULT
LGCIU 1(2)
For the LGCIU 1:
- on the panel 121VU, open
the C/B 52GA then on 49VU,
C/B 1GA. After 15 seconds,
close the C/B 1GA and C/B
52GA
For the LGCIU 2:
- on the panel 121VU, open
the C/B 2GA. After 15
seconds, close the C/B 2GA
Subtask 24-00-00-810-083-A ** ON A/C NOT FOR ALL
M. Navigation
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
34
NAV MMR 1(2) FAULT
MMR1(2)
For the MMR 1:
- On the panel 49VU, open
the C/B 42RT1.
- After 5 seconds, close the
C/B.
For the MMR 2:
- On the panel 121VU, open
the C/B 42RT2.
- After 5 seconds, close the
C/B.
34
NAV TCAS FAULT
TCAS
On the panel 121VU:
- Open the C/B 4SG.
- After 5 seconds, close
the C/B.
34
NAV GPWS FAULT
NAV GPWS TERR DET FAULT
GPWC
On the panel 121VU:
- Open the C/B 3WZ.
- After 5 seconds, close
the C/B.
34
NAV GPS 1(2) FAULT
GPSSU
On the panel 121VU:
- For GPSSU1, open the C/B
2SN1.
- For GPSSU2, open the C/B
2SN2.
- After 5 seconds, close
the C/Bs.
34
NAV RA 1(2) FAULT
XCVR-RA
On the panel 121VU:
- For XCVR-RA 1, open the
C/B 1SA1.
- For XCVR-RA 2, open the
C/B 1SA2.
- After 5 seconds, close
the C/Bs.
Subtask 24-00-00-810-083-D ** ON A/C NOT FOR ALL
M. Navigation
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
34
NAV MMR 1(2) FAULT
MMR1(2)
For the MMR 1:
- On the panel 49VU, open
the C/B 42RT1.
- After 5 seconds, close the
C/B.
For the MMR 2:
- On the panel 121VU, open
the C/B 42RT2.
- After 5 seconds, close the
C/B.
34
NAV TCAS FAULT
T/TISS
On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
34
NAV GPWS FAULT
NAV GPWS TERR DET FAULT
T/TISS
On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
34
NAV ATC/XPDR FAULT
T/TISS
On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
34
NAV GPS 1(2) FAULT
GPSSU
On the panel 121VU:
- For GPSSU1, open the C/B
2SN1.
- For GPSSU2, open the C/B
2SN2.
- After 5 seconds, close
the C/Bs.
34
NAV RA 1(2) FAULT
XCVR-RA
On the panel 121VU:
- For XCVR-RA 1, open the
C/B 1SA1.
- For XCVR-RA 2, open the
C/B 1SA2.
- After 5 seconds, close
the C/Bs.
Subtask 24-00-00-810-084-A ** ON A/C NOT FOR ALL
N. Water/Waste
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
38
Fault messages on the
FAP in the cabin
Vacuum
System
Controller
On the panel 2001VU:
- open the C/B 35MG
- after 30 seconds, close
the C/B.
Subtask 24-00-00-810-085-A
O. Information Systems
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
46
ATSU malfunction
ATSU
On the rear circuit
breaker panel 121VU:
- Open the C/Bs in this
order: 3TX1 and 5TX1.
- After 5 seconds, close
the C/Bs in this order:
5TX1 and 3TX1.
Subtask 24-00-00-810-086-A
P. Engine
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
70
ENG 1(2) IGN A + B FAULT
FADEC and
EIU
On the overhead circuit-breaker panel 49VU and rear circuit-breaker panel 121VU, open then close the circuit breakers of the defective FADEC.
For engine 1:
  • 2KS1 and 4KS1.
    For engine 2:
  • 2KS2 and 4KS2.
70
ENG 1(2) FADEC A(B) FAULT
FADEC
On the overhead circuit-breaker panel 49VU and rear circuit-breaker panel 121VU, open then close the circuit breakers of the defective FADEC.
For engine 1:
  • 2KS1 and 4KS1.
    For engine 2:
  • 2KS2 and 4KS2.
Subtask 24-00-00-810-090-A
Q. Engine Indicating
   (1) Computer Reset Table
ATA
SYSTEM MALFUNCTION
COMPUTER
RESET PROCEDURE
77
Loss of the VIB N1 and VIB
N2 indications on
ENGINE SD page
EVMU
On rear circuit breaker
panel 121VU:
- Open the engine/ENG1 and 2/EVMU
circuit breaker (1EV).
- After five seconds, close the
engine/ENG1 and 2/EVMU
circuit breaker (1EV).
[Rev.8 from Aug 2018] 2026.04.04 04:26:08 UTC