W DOC AIRBUS | TSM A320F

Loss of the MKR Data on the PFD


TASK 34-55-00-810-815-A
Loss of the MKR Data on the PFD


1. Possible Causes
  • RECEIVER-VOR/MKR, 1 [3RS1]
  • ANTENNA-MARKER [1RS]
  • wiring from the MARKER antenna (1RS) to the VOR/MKR receiver 1 (3RS1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-63-00-810-851-A
Loss of the VOR 1 Output Bus by the DMC 1
TSM TASK 31-63-00-810-859-A
Loss of the VOR 1 Output Bus by the DMC 2
TSM TASK 34-55-00-810-801-A
Failure of the VOR/MKR Receiver 1
TSM TASK 34-55-00-810-803-A
Loss of the VOR 1 Data Bus Identified by the EIS 1
TSM TASK 34-55-00-810-804-A
Loss of the VOR 1 Data Bus Identified by the EIS 2
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-004
EIS System Test
AMM 34-55-00-720-001
Functional Test of the VOR/MKR
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
AMM 34-55-18-000-001
Removal of the Marker Antenna
AMM 34-55-18-400-001
Installation of the Marker Antenna
AMM 34-55-31-000-001
Removal of the VOR/MKR Receiver
AMM 34-55-31-400-001
Installation of the VOR/MKR Receiver
3. Fault Confirmation
Subtask 34-55-00-720-058-A
A. Test
   (1) Do the operational test of the VOR/MKR (Test of the MKR reception and identification) AMM 34-55-00-720-001.
4. Fault Isolation
Subtask 34-55-00-810-072-A
A. If the MKR data do not come into view on the F/O PFD only:
Subtask 34-55-00-810-073-A
B. If the MKR data do not come into view on the CAPT PFD only:
Subtask 34-55-00-810-074-A ** ON A/C NOT FOR ALL
C. If the MKR data do not come into view on the F/O PFD and on the CAPT PFD:
   (1) If the BITE test gives the maintenance message VOR 1 RECEIVER:
   (2) If the BITE test does not give the maintenance message VOR 1 RECEIVER:
     (a) If the EIS input test gives the maintenance message DMC 1 : NO VOR 1 DATA or DMC 2 : NO VOR 1 DATA:
     (b) If the EIS input test does not give a maintenance message:
       1 If the fault continues:
         a If the fault continues:
  • do a check and repair the wiring from the MARKER antenna (1RS) to the VOR/MKR receiver 1 (3RS1) ASM 345501.
Subtask 34-55-00-810-074-B ** ON A/C NOT FOR ALL
C. If the MKR data do not come into view on the F/O PFD and on the CAPT PFD:
   (1) If the BITE test gives the maintenance message VOR 1 RECEIVER:
   (2) If the BITE test does not give the maintenance message VOR 1 RECEIVER:
     (a) If the EIS system test gives the maintenance message DMC 1 : NO VOR 1 DATA or DMC 2 : NO VOR 1 DATA:
     (b) If the EIS system test does not give a maintenance message:
       1 If the fault continues:
         a If the fault continues:
  • Do a check and repair the wiring from the MARKER antenna (1RS) to the VOR/MKR receiver 1 (3RS1) ASM 345501.
Subtask 34-55-00-720-059-A
D. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:30 UTC