W DOC AIRBUS | TSM A320F

Failure of the VOR/MKR Receiver 1


TASK 34-55-00-810-801-A
Failure of the VOR/MKR Receiver 1


1. Possible Causes
  • RECEIVER-VOR/MKR, 1 [3RS1]
  • short to ground at the wiring between the circuit breaker (2RS1) and the VOR/MK receiver 1 (3RS1)
  • C/B-NAV/VOR/1 [2RS1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
AMM 34-55-31-000-001
Removal of the VOR/MKR Receiver
AMM 34-55-31-400-001
Installation of the VOR/MKR Receiver
3. Fault Confirmation
Subtask 34-55-00-865-058-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUNAV/VOR/12RS1G13
Subtask 34-55-00-740-050-A
B. Test
   (1) If the circuit breaker (2RS1) trips, refer to Para. 4. C. of this trouble shooting procedure.
   (2) Do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
  • If the BITE test is not possible, refer to Para. 4. B. of this trouble shooting procedure.
4. Fault Isolation
Subtask 34-55-00-810-050-B
A. If the circuit breaker (2RS1) is closed, and if the BITE test gives the maintenance message VOR1 (3RS1):
Subtask 34-55-00-810-051-A
B. If the circuit breaker (2RS1) is closed and if the BITE test is not possible
  • do a check for 115VAC at pin AC/2 of the VOR/MKR receiver 1.
   (1) If there is no 115VAC:
  • do a check of the wiring of the 115VAC signal from circuit breaker (2RS1) to VOR/MKR receiver 1 (3RS1) ASM 345501.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • replace the C/B-NAV/VOR/1 (2RS1).
   (2) If there is 115VAC:
  • do a check of the wiring of the ground signal at VOR/MKR receiver 1 pin AC/3.
     (a) If there is no continuity:
  • repair the above wiring.
Subtask 34-55-00-810-084-A
C. If the circuit breaker (2RS1) is open:
  • close this circuit breaker.
   (1) If the circuit breaker (2RS1) trips:
     (a) If this circuit breaker stays closed:
       1 If the circuit breaker trips again:
     (b) If this circuit breaker trips again:
  • do a check for a short to ground at the wiring between the circuit breaker (2RS1) and the VOR/MK receiver 1 (3RS1) ASM 345501.
       1 If there is a short to ground:
  • repair the above wiring.
       2 If there is no short to ground:
  • replace the C/B-NAV/VOR/1 [2RS1] .
       3 Install the VOR/MKR receiver 1
AMM 34-55-31-400-001.
Subtask 34-55-00-740-051-A
D. Do the test given in Para. 3.