Cabin Lights - All Cabin Lights Flicker
TASK 33-21-00-810-806-A
Cabin Lights - All Cabin Lights Flicker
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-21-00-860-055-A
Subtask 33-21-00-810-060-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:55 UTC
Cabin Lights - All Cabin Lights Flicker
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-21-00-810-811-A | The steady-state Operating Frequency of the Integrated Drive Generator (IDG1) is out of the 390Hz-410Hz range |
| TSM TASK 24-21-00-810-812-A | The steady-state Operating Frequency of the Integrated Drive Generator (IDG2) is out of the 390Hz-410Hz range |
Subtask 33-21-00-860-055-A
A. Not Applicable
4. Fault IsolationSubtask 33-21-00-810-060-A
A. Do the following steps:
(1) Do the troubleshooting procedure of the Integrated Drive Generators (Ref. TSM TASK 24-21-00-810-811) and/or (Ref. TSM TASK 24-21-00-810-812).
(1) Do the troubleshooting procedure of the Integrated Drive Generators (Ref. TSM TASK 24-21-00-810-811) and/or (Ref. TSM TASK 24-21-00-810-812).