The steady-state Operating Frequency of the Integrated Drive Generator (IDG2) is out of the 390Hz-410Hz range


TASK 24-21-00-810-812-A
The steady-state Operating Frequency of the Integrated Drive Generator (IDG2) is out of the 390Hz-410Hz range


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-21-00-730-040
System Test of the IDG Frequency (P/N 740119)
AMM 24-21-51-000-040
Removal of the Integrated Drive Generator - IDG 1(2)
AMM 24-21-51-000-803
Removal of the Integrated Drive Generator - IDG 1(2)
AMM 24-21-51-400-040
Installation of the Integrated Drive Generator - IDG 1(2)
AMM 24-21-51-400-803
Installation of the Integrated Drive Generator - IDG 1(2)
AMM 24-22-33-000-001
Removal of the EGIU-1(2)
AMM 24-22-33-400-002
Installation of the EGIU-1(2)
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
AMM 71-00-00-710-003
Engine Automatic Start
AMM 71-00-00-710-027
Engine Shutdown
AMM 71-00-00-860-814
Shutdown of the Engine
AMM 71-00-00-860-823
Start the Engine (Normal Automatic Start)
3. Fault Confirmation
Subtask 24-21-00-860-052-B ** ON A/C NOT FOR ALL
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
     (c) Start the engine 2 AMM 71-00-00-710-003.
Subtask 24-21-00-860-052-E ** ON A/C NOT FOR ALL
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
     (c) Start engine 2 AMM 71-00-00-860-823.
Subtask 24-21-00-710-068-B
B. Test
ACTION
RESULT
1.On the ECAM control panel:
  • push the ELEC key to get the ELEC page.
On the lower ECAM DU:
  • the frequency parameter of the IDG2 is amber.
NOTE: In normal operation, the color of the IDG frequency parameter is green.
4. Fault Isolation
Subtask 24-21-00-810-061-B ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
   (1) If the IDG2 frequency parameter stays amber:
     (a) The frequency parameter value is out of the 390Hz-410Hz range:
       1 If the IDG2 frequency parameter stays amber:
     (b) The frequency parameter value is out of the 363Hz-433Hz range:
Subtask 24-21-00-810-061-D ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
   (1) If the IDG2 frequency parameter stays amber:
Subtask 24-21-00-810-061-F ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
   (1) If the IDG2 frequency parameter stays amber:
Subtask 24-21-00-710-069-B
B. Do the test given in Para. 3.
5. Close-up
Subtask 24-21-00-860-053-B ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Stop the engine 2 AMM 71-00-00-710-027.
   (2) Do the EIS stop procedure
AMM 31-60-00-860-002.
   (3) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
Subtask 24-21-00-860-053-E ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Stop engine 2 AMM 71-00-00-860-814.
   (2) Do the EIS stop procedure
AMM 31-60-00-860-002.
   (3) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.