FDIMU Inoperative
TASK 31-36-00-810-898-A
FDIMU Inoperative
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-740-164-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-36-00-810-110-C ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:05 UTC
FDIMU Inoperative
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-33-00-810-801-A | DFDR Inoperative |
| TSM TASK 31-33-00-810-805-A | Accelerometer Fault |
| TSM TASK 31-33-00-810-806-A | DFDR Playback Data Fault |
| TSM TASK 31-33-00-810-807-A | No AC Ident |
| TSM TASK 31-36-00-810-899-A | FDIMU Battery |
| TSM TASK 31-36-00-810-900-A | FDIMU PCMCIA MEDIA |
| AMM 23-51-34-400-001 | Installation of the Audio Management Unit (AMU) (1RN) |
| AMM 31-36-00-740-008 | Access to the Parameter Call-Up Menus |
| AMM 31-36-00-740-012 | Test of the Flight Data Interface and Management Unit (FDIMU) |
| ASM 313601 | |
| AMM 31-36-34-000-002 | Removal of the FDIU/DMU (FDIMU) |
| AMM 31-36-34-400-002 | Installation of the FDIU/DMU (FDIMU) |
| ASM 313701 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-36-00-740-164-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-36-00-810-110-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message as listed below do the related trouble shooting procedure:
(2) If the fault continues:
2 FDIMU (10TV) connector AA/12C and AMU (1RN) pin AB/2J
3 FDIMU (10TV) connector AA/12D and AMU (1RN) pin AB/2K
4 FDIMU (10TV) connector AB/4C and CFDIU (1TW) connector AB/11D
5 FDIMU (10TV) connector AB/4D and CFDIU (1TW) connector AB/11E
6 FDIMU (10TV) connector AA/12E and CFDIU (1TW) connector AB/8B
7 FDIMU (10TV) connector AA/12F and CFDIU (1TW) connector AB/8C.
(c) If there is no 115 VAC:
2 from FDIMU AC/7 to ground
3 from FDIMU AA/15J to ground
4 from FDIMU AA/15K to ground
5 from FDIMU AB/15J to ground
6 from FDIMU AB/15K to ground.
(4) If the ECAM shows the message "31-00 DAR" and a DAR is not installed:
Subtask 31-36-00-740-165-A ** ON A/C NOT FOR ALL - "DFDR" (Ref. TSM TASK 31-33-00-810-801)
- "ACCELEROMETER" (Ref. TSM TASK 31-33-00-810-805)
- "DFDR PLAYBACK" (Ref. TSM TASK 31-33-00-810-806)
- "NO AC IDENT" (Ref. TSM TASK 31-33-00-810-807)
- "PCMCIA MEDIA" (Ref. TSM TASK 31-36-00-810-900)
- "BATTERY" (Ref. TSM TASK 31-36-00-810-899)
(2) If the fault continues:
- replace SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001
- if fault continues, replace SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001
- if fault continues, replace AMU [1RN] AMM 31-55-34-000-001 and AMM 23-51-34-400-001.
- make sure that the CB 5TV is closed
- do a check for 115 VAC at the FDIMU (10TV) connectors AC/1 and AC/7 ASM 313601.
- replace the DMU/FDIU (FDIMU) [10TV] AMM 31-36-34-000-002 and AMM 31-36-34-400-002.
- do a check and repair the wiring between the DMU/FDIU (FDIMU) [10TV] and SDAC-1 [1WV1] , SDAC-2 [1WV2] , AMU [1RN] and CFDIU [1TW] ASM 313601 and ASM 313701:
2 FDIMU (10TV) connector AA/12C and AMU (1RN) pin AB/2J
3 FDIMU (10TV) connector AA/12D and AMU (1RN) pin AB/2K
4 FDIMU (10TV) connector AB/4C and CFDIU (1TW) connector AB/11D
5 FDIMU (10TV) connector AB/4D and CFDIU (1TW) connector AB/11E
6 FDIMU (10TV) connector AA/12E and CFDIU (1TW) connector AB/8B
7 FDIMU (10TV) connector AA/12F and CFDIU (1TW) connector AB/8C.
(c) If there is no 115 VAC:
- do a check and repair the wiring between the DMU/FDIU (FDIMU) [10TV] and CB 5TV and Ground points ASM 313601:
2 from FDIMU AC/7 to ground
3 from FDIMU AA/15J to ground
4 from FDIMU AA/15K to ground
5 from FDIMU AB/15J to ground
6 from FDIMU AB/15K to ground.
(4) If the ECAM shows the message "31-00 DAR" and a DAR is not installed:
- make sure that the PCMCIA configuration of the FDIMU database is correct.
NOTE: A DAR fault message also can occur on the ECAM, if the PCMCIA configuration of the FDIMU database is customized. For example the FDIMU generates a DAR fault message, if a PCMCIA card is not installed or the PCMCIA DAR space is full and the CFDS failure inhibition is not set. For details refer to the vendor documentation of the FDIMU.
- do a check of the alpha call-up "DISI1" AMM 31-36-00-740-008.
- check if pin AA/13E of the FDIMU is grounded ASM 313601.
- repair the wiring and remove the ground from pin AA/13E.
- replace the FDIMU AMM 31-36-34-000-002, AMM 31-36-34-400-002.
B. Do the test given in Para. 3.