W DOC AIRBUS | TSM A320F

Loss of the WHC 2


TASK 30-42-00-810-828-A
Loss of the WHC 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 30-42-00-810-801-A
Loss of the Left Windshield Temperature Sensor
AMM 30-42-00-710-001
Operational Test of the Windshield Anti-Icing and Defogging
ASM 304202
AMM 30-42-34-000-001
Removal of the Window Heat Computer (WHC)
AMM 30-42-34-400-001
Installation of the Window Heat Computer (WHC)
3. Fault Confirmation
Subtask 30-42-00-710-104-A
A. Test
   (1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation
Subtask 30-42-00-810-077-A
A. If the test gives the maintenance message WHC 2DG2:
Subtask 30-42-00-810-097-A
B. If the test gives the maintenance message R WSHLD SENSOR (3DG2)/WHC2 (2DG2):
   (1) Do a check of the R Windshield Temperature Information (Ref. TSM TASK 30-42-00-810-801).
     (a) Verify if the resistance of the temperature sensor connected to the R windshield (3DG2) is out of the tolerance ASM 304202 and
For example, for OAT=20°C, the sensor value must be between 592 Ohms and 608 Ohms. If the sensor is out of tolerance, refer to (Ref. TSM TASK 30-42-00-810-801) to isolate the suspected sensor and to connect a serviceable sensor to the WHC.
5. Close-up
Subtask 30-42-00-710-121-A
A. Do the operational test given in Para.3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:43 UTC