W DOC AIRBUS | TSM A320F

Loss of the WHC 1


TASK 30-42-00-810-827-A
Loss of the WHC 1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 30-42-00-810-801-A
Loss of the Left Windshield Temperature Sensor
AMM 30-42-00-710-001
Operational Test of the Windshield Anti-Icing and Defogging
ASM 304201
AMM 30-42-34-000-001
Removal of the Window Heat Computer (WHC)
AMM 30-42-34-400-001
Installation of the Window Heat Computer (WHC)
3. Fault Confirmation
Subtask 30-42-00-710-102-A
A. Test
   (1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation
Subtask 30-42-00-810-076-A
A. If the test gives the maintenance message WHC 2DG1:
Subtask 30-42-00-810-096-A
B. If the test gives the maintenance message L WSHLD SENSOR (3DG1)/WHC (2DG1):
   (1) Do a check of the L Windshield Temperature Information (Ref. TSM TASK 30-42-00-810-801).
     (a) Verify if the resistance of the temperature sensor connected to the L windshield (3DG1) is out of the tolerance ASM 304201 and
For example, for OAT=20°C, the sensor value must be between 592 Ohms and 608 Ohms. If the sensor is out of tolerance, refer to (Ref. TSM TASK 30-42-00-810-801) to isolate the suspected sensor and to connect a serviceable sensor to the WHC.
5. Close-up
Subtask 30-42-00-710-120-A
A. Do the operational test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:43 UTC