Intermittent Indication of HYD B RSVR LO LVL and HYD B RSVR OVHT on ECAM DU
TASK 29-12-00-810-814-A
Intermittent Indication of HYD B RSVR LO LVL and HYD B RSVR OVHT on ECAM DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 29-12-00-865-060-A
Subtask 29-12-00-810-066-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:23 UTC
Intermittent Indication of HYD B RSVR LO LVL and HYD B RSVR OVHT on ECAM DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 29-12-00-810-802-A | Overheat Indication of the Blue Hydraulic System |
| TSM TASK 29-12-00-810-803-A | Loss of the Correct Quantity in the Blue Hydraulic Reservoir |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 29-12-00-865-060-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-12-00-860-065-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| 49VU | SDAC/1 AND 2/28VDC/ESS BUS | 12WV | F05 |
| 49VU | SDAC/1/SPLY | 3WV | F04 |
| 49VU | SDAC/2/26VAC SYNC/AC ESS BUS | 6WV | F03 |
| 49VU | SDAC/1/26VAC SYNC/AC ESS BUS | 5WV | F02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SDAC/1/BUS1/26VAC SYNC AC | 9WV | Q04 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/LOW/LVL/IND | 1832GQ | N32 |
| 121VU | HYDRAULIC/HYD/QTY/IND | 1831GQ | P35 |
| 121VU | EIS/SDAC/2/SPLY | 2WV | Q06 |
| 121VU | EIS/SDAC/2/BUS1/26VAC SYNC AC | 10WV | Q05 |
| 121VU | EIS/SDAC/1/BUS2/26VAC SYNC AC | 7WV | Q03 |
| 121VU | EIS/SDAC/2/BUS2/26VAC SYNC AC | 8WV | Q02 |
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) Look for fault indications on the upper ECAM DU.
4. Fault Isolation(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) Look for fault indications on the upper ECAM DU.
Subtask 29-12-00-810-066-A ** ON A/C NOT FOR ALL
A. If the Fault Confirmation gives:
-the messages HYD B RSVR LO LVL and HYD B RSVR on the upper ECAM DU:
(a) Close these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 9WV.
(b) Open these circuit breakers:
- 2WV,
- 6WV,
- 8WV and
- 10WV.
(3) If the fault messages go off:
Subtask 29-12-00-810-066-B ** ON A/C NOT FOR ALL -the messages HYD B RSVR LO LVL and HYD B RSVR on the upper ECAM DU:
- Open these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 9WV.
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(a) Close these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 9WV.
(b) Open these circuit breakers:
- 2WV,
- 6WV,
- 8WV and
- 10WV.
(3) If the fault messages go off:
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- Do the troubleshooting as given in the subsequent references:
- (Ref. TSM TASK 29-12-00-810-803) and
- (Ref. TSM TASK 29-12-00-810-802).
A. If the Fault Confirmation gives:
-the messages HYD B RSVR LO LVL and HYD B RSVR on the upper ECAM DU:
(a) Close these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 1832GQ.
(b) Open these circuit breakers:
- 2WV,
- 6WV,
- 8WV and
- 10WV.
(3) If the fault messages go off:
Subtask 29-12-00-860-066-A -the messages HYD B RSVR LO LVL and HYD B RSVR on the upper ECAM DU:
- Open these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 1832GQ.
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(a) Close these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 1832GQ.
(b) Open these circuit breakers:
- 2WV,
- 6WV,
- 8WV and
- 10WV.
(3) If the fault messages go off:
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- Do the troubleshooting as given in these references:
- (Ref. TSM TASK 29-12-00-810-803) and
- (Ref. TSM TASK 29-12-00-810-802).
B. Do the fault confirmation procedure as given in Para. 3. to make sure that the operation is correct.