W DOC AIRBUS | TSM A320F

Intermittent Indication of HYD B RSVR LO LVL and HYD B RSVR OVHT on ECAM DU


TASK 29-12-00-810-814-A
Intermittent Indication of HYD B RSVR LO LVL and HYD B RSVR OVHT on ECAM DU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 29-12-00-810-802-A
Overheat Indication of the Blue Hydraulic System
TSM TASK 29-12-00-810-803-A
Loss of the Correct Quantity in the Blue Hydraulic Reservoir
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
AMM 31-60-00-860-001
EIS Start Procedure
3. Fault Confirmation
Subtask 29-12-00-865-060-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
49VUSDAC/1 AND 2/28VDC/ESS BUS12WVF05
49VUSDAC/1/SPLY3WVF04
49VUSDAC/2/26VAC SYNC/AC ESS BUS6WVF03
49VUSDAC/1/26VAC SYNC/AC ESS BUS5WVF02
** ON A/C NOT FOR ALL
121VUEIS/SDAC/1/BUS1/26VAC SYNC AC9WVQ04
** ON A/C ALL
121VUHYDRAULIC/LOW/LVL/IND1832GQN32
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
121VUEIS/SDAC/2/SPLY2WVQ06
121VUEIS/SDAC/2/BUS1/26VAC SYNC AC10WVQ05
121VUEIS/SDAC/1/BUS2/26VAC SYNC AC7WVQ03
121VUEIS/SDAC/2/BUS2/26VAC SYNC AC8WVQ02
Subtask 29-12-00-860-065-A
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
   (2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
   (3) Look for fault indications on the upper ECAM DU.
4. Fault Isolation
Subtask 29-12-00-810-066-A ** ON A/C NOT FOR ALL
A. If the Fault Confirmation gives:

-the messages HYD B RSVR LO LVL and HYD B RSVR on the upper ECAM DU:

  • Open these circuit breakers:
    - 3WV,
    - 5WV,
    - 7WV and
    - 9WV.
   (1) If the fault messages go off:
   (2) If the fault continues:
     (a) Close these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 9WV.
     (b) Open these circuit breakers:
- 2WV,
- 6WV,
- 8WV and
- 10WV.
   (3) If the fault messages go off:
   (4) If the fault continues:
Subtask 29-12-00-810-066-B ** ON A/C NOT FOR ALL
A. If the Fault Confirmation gives:

-the messages HYD B RSVR LO LVL and HYD B RSVR on the upper ECAM DU:

  • Open these circuit breakers:
    - 3WV,
    - 5WV,
    - 7WV and
    - 1832GQ.
   (1) If the fault messages go off:
   (2) If the fault continues:
     (a) Close these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 1832GQ.
     (b) Open these circuit breakers:
- 2WV,
- 6WV,
- 8WV and
- 10WV.
   (3) If the fault messages go off:
   (4) If the fault continues:
Subtask 29-12-00-860-066-A
B. Do the fault confirmation procedure as given in Para. 3. to make sure that the operation is correct.